Submitted by Irvana Coutinho (irvana@ufpa.br) on 2011-03-30T17:58:27Z
No. of bitstreams: 2
VIEIRA, João Paulo AbreuPPGEngenharia Elétrica.pdf: 1787430 bytes, checksum: 12e80b0ff02b230fff69887679ac8338 (MD5)
license_rdf: 22876 bytes, checksum: 0a4e855daae7a181424315bc63e71991 (MD5) / Made available in DSpace on 2011-03-30T17:58:27Z (GMT). No. of bitstreams: 2
VIEIRA, João Paulo AbreuPPGEngenharia Elétrica.pdf: 1787430 bytes, checksum: 12e80b0ff02b230fff69887679ac8338 (MD5)
license_rdf: 22876 bytes, checksum: 0a4e855daae7a181424315bc63e71991 (MD5)
Previous issue date: 2009 / Na presente tese propõe-se uma metodologia de ajuste ótimo dos controladores do conversor interligado ao rotor de aerogeradores de indução duplamente excitados (DFIG), utilizando algoritmos genéticos (AG), com o objetivo de melhorar a segurança e a robustez do sistema elétrico de potência, permitindo que os aerogeradores DFIG participem da gestão técnica do sistema. Para garantir este objetivo, é utilizada uma estratégia de proteção do tipo “crow-bar” durante a falta, mantendo o conversor interligado ao rotor conectado à máquina. Imediatamente após a eliminação da falta, o “crow-bar” é desativado, e simultaneamente os controladores ótimos do conversor interligado ao rotor são acionados, previamente ajustados pelo AG, a fim de melhorar a capacidade de sobrevivência a afundamentos de tensão “ridethrough capability” e a margem de estabilidade global do sistema elétrico. Para validação da metodologia ótima desenvolvida foram realizadas simulações computacionais utilizando uma rede elétrica real, em três condições operacionais distintas. / It is proposed in this thesis a methodology to obtain optimal controllers gains for the rotorside converter of doubly fed induction generators (DFIGs) using a genetic algorithm approach. The main objective is to enhance the operational security and robustness of the power system, by a more effective contribution of the DFIG controllers to the system controllability. To reach this goal, the crow-bar protection scheme is activated during the fault period when severe voltage sags occur in order to maintain the rotor-side converter connected to the DFIG. Immediately after the fault is cleared the crow-bar protection scheme is deactivated and simultaneously the rotor-side converter optimal controllers are turned on which permits the improvement of the converter ride-through capability and also contribute to enhance the overall power system stability margin. The effectiveness of this proposed methodology was assessed for the DFIG-based plants using a real electrical network, in three different operational conditions.
Identifer | oai:union.ndltd.org:IBICT/oai:repositorio.ufpa.br:2011/2079 |
Date | 12 January 2009 |
Creators | VIEIRA, João Paulo Abreu |
Contributors | NUNES, Marcus Vinícius Alves, BEZERRA, Ubiratan Holanda |
Publisher | Universidade Federal do Pará, Programa de Pós-Graduação em Engenharia Elétrica, UFPA, Brasil, Instituto de Tecnologia |
Source Sets | IBICT Brazilian ETDs |
Language | Portuguese |
Detected Language | Portuguese |
Type | info:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/doctoralThesis |
Source | reponame:Repositório Institucional da UFPA, instname:Universidade Federal do Pará, instacron:UFPA |
Rights | info:eu-repo/semantics/openAccess |
Page generated in 0.0016 seconds