Return to search

Caracteriza??o de ?gua de lavagem de filtros em esta??es de tratamento de ?gua de filtra??o direta

Submitted by Automa??o e Estat?stica (sst@bczm.ufrn.br) on 2016-02-05T22:39:44Z
No. of bitstreams: 1
HildericaLimaCampos_DISSERT.pdf: 1518298 bytes, checksum: 41cac6ede5b5c76dd7cadea1205d049e (MD5) / Approved for entry into archive by Arlan Eloi Leite Silva (eloihistoriador@yahoo.com.br) on 2016-02-16T19:46:12Z (GMT) No. of bitstreams: 1
HildericaLimaCampos_DISSERT.pdf: 1518298 bytes, checksum: 41cac6ede5b5c76dd7cadea1205d049e (MD5) / Made available in DSpace on 2016-02-16T19:46:12Z (GMT). No. of bitstreams: 1
HildericaLimaCampos_DISSERT.pdf: 1518298 bytes, checksum: 41cac6ede5b5c76dd7cadea1205d049e (MD5)
Previous issue date: 2015-02-09 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior - CAPES / O tratamento de ?gua para abastecimento ? considerado como um grande benef?cio,
tendo em vista que, se for realizado de forma eficiente, propicia sa?de ?s pessoas.
Entretanto, ao considerar que uma ETA (Esta??o de Tratamento de ?gua) ? uma
ind?stria, pois em seu processo produtivo h? insumos e res?duos, ? necess?rio que
haja avalia??o e monitoramento constantes em cada ETA para verificar a melhor e
mais adequada maneira de tratar e dispor seus res?duos, minimizando, portanto, os
potenciais impactos ao meio ambiente. Os res?duos mais relevantes em ETA de
filtra??o r?pida s?o os provenientes das ?guas de lavagem de filtros. A realidade
mais observada em nosso pa?s ? o lan?amento destes res?duos (sem tratamento)
em mananciais, os quais s?o utilizados, na maioria das vezes, como fonte de
abastecimento de uma popula??o a jusante. O presente estudo avaliou indicadores
quantitativos e qualitativos de ?gua de lavagem de filtros em tr?s ETA - Itaitinga,
Maranguape e Pacatuba. Verificou-se que a ETA Maranguape, em termos de
capacidade instalada, ? a de maior porte. A ETA Itaitinga ? a que mais consome
?gua na lavagem de filtros. A ETA Pacatuba exibiu maior concentra??o de s?lidos
sediment?veis e suspensos totais, al?m de demanda qu?mica de oxig?nio e alum?nio
na ?gua de lavagem dos filtros. Os par?metros s?lidos sediment?veis e s?lidos
suspensos totais de todas as ETA estavam fora do padr?o de lan?amento de
efluentes em corpo aqu?tico preconizado pela resolu??o 154/2002 da SEMACE
(Superintend?ncia Estadual do Meio Ambiente do Cear?). Conclui-se que a ?gua de
lavagem dos filtros das ETA em estudo ultrapassam os valores permitidos em
legisla??o para serem descartados diretamente em manancial. Sugere-se como
alternativa de tratamento de res?duos, a constru??o de lagoas de sedimenta??o de
lodo e ainda, como forma de reaproveitamento da ?gua, o processo de recircula??o. / The water supply and treatment is considered as a great benefit considering that, if
done efficiently, provides public health. However, considering the WTP (Water
Treatment Plant) is an industry, with its inputs and waste generation, they must be
constantly evaluated and monitored to verify the best and most appropriate way to
process and dispose their waste, minimizing therefore the potential impacts to the
environment. By volume, the most significant waste is the rapid filter backwash water.
It is very common the disposal of this waste without treatment in water sources,
which are used, for the most part, as a water supply source of a downstream
population. This study evaluated quantitative and qualitative parameters in filter
backwash water in three WTP - Itaitinga, Maranguape and Pacatuba, located in
Cear? State, northeast of Brazil. It was found that the Maranguape WTP, in terms of
treatment capacity, is the larger. The Itaitinga WTP is the one that consumes more
water during filters washing. The Pacatuba WTP exhibited higher concentration of
total suspended and settleable solids, COD and aluminum in the filters backwash
water. It is noteworthy that the settleable solids and total suspended solids in all three
WTP are above the effluent discharge standard recommended by Resolution
154/2002 of SEMACE (State Superintendent of Environment of Cear?). It was
concluded that the filter backwash water from the study WTP exceeded the allowed
values for legislation to be disposed directly into surface water bodies. It is suggested
as an alternative to treat and recycle the filter backwashing water the construction of
sludge settling ponds.

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.ufrn.br:123456789/19779
Date09 February 2015
CreatorsCampos, Hilderica Lima
Contributors37695045268, http://lattes.cnpq.br/7133712883742750, Andrade Neto, C?cero Onofre de, 05712939487, http://lattes.cnpq.br/9961536190401150, Silva, Fernando Jos? Ara?jo da, 24546925387, http://lattes.cnpq.br/1248533911274093, Duarte, Marco Ant?nio Calazans, Ara?jo, Andr? Lu?s Calado
PublisherUniversidade Federal do Rio Grande do Norte, PROGRAMA DE P?S-GRADUA??O EM ENGENHARIA SANIT?RIA, UFRN, Brasil
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Sourcereponame:Repositório Institucional da UFRN, instname:Universidade Federal do Rio Grande do Norte, instacron:UFRN
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0026 seconds