Controle de vibrações induzidas em uma laje de academia de ginástica com a utilização de amortecedores de massa sintonizados (AMS) / Induced vibration control of a gym slab using mutiple tuned mass dampers (TMD)

Dissertação (mestrado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Civil e Ambiental, 2007. / Submitted by Luis Felipe Souza (luis_felas@globo.com) on 2008-11-28T16:23:54Z
No. of bitstreams: 1
Dissertacao_2007_DanielValencaLima.pdf: 2065088 bytes, checksum: 0f9fa417b67480ff16a5ca97b0678010 (MD5) / Approved for entry into archive by Georgia Fernandes(georgia@bce.unb.br) on 2009-01-21T13:43:45Z (GMT) No. of bitstreams: 1
Dissertacao_2007_DanielValencaLima.pdf: 2065088 bytes, checksum: 0f9fa417b67480ff16a5ca97b0678010 (MD5) / Made available in DSpace on 2009-01-21T13:43:45Z (GMT). No. of bitstreams: 1
Dissertacao_2007_DanielValencaLima.pdf: 2065088 bytes, checksum: 0f9fa417b67480ff16a5ca97b0678010 (MD5) / Neste trabalho apresenta-se a análise dinâmica da laje de um edifício comercial localizado na
cidade de Brasília, Brasil, utilizado como academia de ginástica. É avaliada a sua resposta
quando submetida ao carregamento oriundo das atividades humanas de pular e dançar. A
estrutura é modelada em elementos finitos e analisada inicialmente sob regime estático. Em
seguida, é feita uma análise modal para se obter as freqüências naturais e os modos de
vibração. Sendo identificadas freqüências consideravelmente baixas, próximas às freqüências
que caracterizam o carregamento devido à atividade humana, faz-se então uma análise
transiente, submetendo-se a estrutura a uma carga dinâmica que simula a atividade humana
típica de academia. A resposta da estrutura quando submetida à carga dinâmica é avaliada,
então, quanto a critérios de normas internacionais que estabelecem deslocamentos e
acelerações admissíveis. Uma vez que são constatados níveis de vibração superiores aos
recomendados pelos diferentes códigos, faz-se necessário o estudo de um mecanismo de
controle capaz de reduzir as vibrações obtidas. Assim, são elaboradas propostas de controle
estrutural para atenuação de vibrações excessivas por meio da instalação de Amortecedores de Massa Sintonizados (AMS) na estrutura estudada. Os resultados encontrados são apresentados neste trabalho e analisados criticamente.
__________________________________________________________________________________ ABSTRACT / In this work it’s presented a dynamic analysis in a slab of a commercial building in the city of
Brasília, Brazil, which is used as a gym. Its behavior is evaluated when submitted to the load
due to the human activities of jumping and dancing. The structure is modeled by finite
elements and is primarily analyzed under static regime. Afterwards a modal analysis is made
in order to obtain its natural frequencies and the vibration modes. Since considerably low
frequencies are identified, close to the characteristic frequencies of the load due to human
activities, a transient analysis is then performed, submitting the structure to a dynamic load
that simulates typical human activities in gyms. Then the structure’s response due to the
dynamic load is evaluated with respect to admissible displacement and acceleration criteria,
established by international codes. Once vibration levels in the structure are found to be
higher then the permitted levels described by these codes, it’s understood that a structural
control is necessary in order to reduce the observed vibrations. Thus, a study of some
structural control alternatives for attenuating excessive vibrations is done by the use of Tuned
Mass Damper (TMD) in the studied structure. The results obtained are presented in this work
and critically analyzed.

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unb.br:10482/1117
Date11 1900
CreatorsLima, Daniel Valença Fiuza
ContributorsCarvalho, Graciela Nora Doz de, Avila, Suzana Moreira
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Sourcereponame:Repositório Institucional da UnB, instname:Universidade de Brasília, instacron:UNB
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0022 seconds