Return to search

Cateter esofágico para medição de temperatura durante procedimento de ablação cardíaca por rádiofrequência (RF)

Dissertação (mestrado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Elétrica, 2009. / Submitted by Allan Wanick Motta (allan_wanick@hotmail.com) on 2010-04-23T14:35:56Z
No. of bitstreams: 1
2009_RuiAlvesdeSousa.pdf: 637987 bytes, checksum: acdd9243f829ef4d74f8fc004e971ba4 (MD5) / Approved for entry into archive by Lucila Saraiva(lucilasaraiva1@gmail.com) on 2010-04-30T22:02:15Z (GMT) No. of bitstreams: 1
2009_RuiAlvesdeSousa.pdf: 637987 bytes, checksum: acdd9243f829ef4d74f8fc004e971ba4 (MD5) / Made available in DSpace on 2010-04-30T22:02:15Z (GMT). No. of bitstreams: 1
2009_RuiAlvesdeSousa.pdf: 637987 bytes, checksum: acdd9243f829ef4d74f8fc004e971ba4 (MD5)
Previous issue date: 2009 / O trabalho visou abordar o problema de fístula atrio-esôfagica durante o procedimento de ablação por RF. Através de um modelo computacional em elementos finitos obtemos dados sobre o comportamento da temperatura ao longo da região entre átrio e esôfago e sua propagação durante o procedimento de ablação. Estes dados nos permitiram projetar o cateter esôfagico o que foi desenvolvido, este cateter tinha uma acurácia de 0,05 C com P< 0; 05 (ANOVA) variando de 25 C a 75 C. A busca por resultados mais acurados e precisos nos levou a desenvolver como complemento um equipamento para mensurar o tempo de relaxamento em tecidos. O equipamento desenvolvido obteve os seguintes resultados para agar gel: tempo de relaxamento de 4,69 segundos e difusitividade térmica de 1; 3679e��7 2,76e-9 m2=s, resultado 6 % divergente do cálculo teóricoof 1,4559e-7 m2=s. _______________________________________________________________________________________ ABSTRACT / The atrial-esophageal fistula is a potentially fatal complication of radiofrequency cardiac ablation. We developed a finite element model in order to determine the behavior of temperature along the region between the atrium and esophagus during the ablation procedure. The results of the model were used in order to design, build and test an esophageal catheter. The catheter accuracy was 0,05 C in the 25 C - 75 C range (p<0,05). In addition, we developed an instrument to measure the thermal relaxation time of agar a commonly used substance for the study of ablation procedures. The results showed that its thermal relaxation time and thermal diffusivity was of 4,69 seconds and 1; 3679e��7 2; 76e��9m2=s respectively.

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unb.br:10482/4390
Date January 2009
CreatorsSousa, Rui Alves de
ContributorsSantos, Ícaro dos
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Sourcereponame:Repositório Institucional da UnB, instname:Universidade de Brasília, instacron:UNB
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0024 seconds