Return to search

Reprodutibilidade da curva de pressão intraocular de 24 horas em pacientes com glaucoma e suspeita de glaucoma / Reproducibility of 24-hour intraocular pressure curve in patients with glaucoma and suspected glaucoma

Made available in DSpace on 2016-05-17T16:51:11Z (GMT). No. of bitstreams: 0
Previous issue date: 2015-06-10. Added 1 bitstream(s) on 2016-05-17T16:54:44Z : No. of bitstreams: 1
000858467.pdf: 2346803 bytes, checksum: 8eb03d0cf9e13d4b51d80092c6ea5380 (MD5) / Foi avaliada a reprodutibilidade das medidas de pressão intraocular (PIO) nos mesmos horários da curva tensional diária (CTD) de 24 horas, com três repetições. Foram estudados 33 indivíduos com glaucoma e suspeita de glaucoma sem tratamento. Todos os participantes foram submetidos a 3 CTDs de 24 horas. Os pacientes foram internados e as medidas foram realizadas às 9:00 hs, 12:00 hs, 15:00 hs, 18:00 hs, 21:00 hs, 24:00 hs e 6:00 hs com tonômetro de aplanação de Goldmann (TAG). A medida das 6:00 hs também foi realizada no leito, utilizando-se um tonômetro manual de Perkins antes da medida com o TAG. Uma segunda CTD de 24 horas foi realizada após um intervalo entre uma e três semanas e uma terceira após mesmo intervalo. A reprodutibilidade foi avaliada em cada horário da CTD de 24 horas com o coeficiente de correlação intraclasse (CCI) e os gráficos de Bland- Altman. Nos gráficos de Bland-Altman considerou-se como limite de concordância uma diferença de até 3 mmHg entre as medidas. O CCI variou de 0,736 a 0,917 nos diferentes horários, estando a maioria deles acima de 0,800. Nos gráficos de Bland- Altman, a porcentagem de pontos dentro do limite de concordância de 3 mmHg variou de 72,7 a 97,0%, sendo na maioria das observações acima de 80%. Concluiuse que as medidas da PIO em cada momento da CTD de 24 horas nas três repetições apresentaram excelente ou boa reprodutibilidade em indivíduos com glaucoma e suspeita de glaucoma / The reproducibility of measurements of intraocular pressure (IOP) at the same points of the 24-hour daily tension curve (DTC) with three replications was evaluated. Thirtythree untreated subjects with glaucoma and suspected glaucoma were studied. All participants underwent three 24-hour DTCs. Briefly, participants were hospitalized and IOP measurements obtained at 9:00 AM, noon, 3:00 PM, 6:00 PM, 9:00 PM, midnight and 6:00 AM using a Goldmann applanation tonometer. The 6:00 AM measurement was also obtained at bedside with a handheld Perkins tonometer prior to Goldmann tonometry. A second 24-hour DTC was performed 1 to 3 weeks after the first, and a third and final curve was obtained 1 to 3 weeks after the second. Reproducibility of measurements at each time point of the 24-hour DTC was assessed by means of the intraclass correlation coefficient (ICC) and Bland-Altman plots. A 3-mmHg difference in IOP was defined as the limit of agreement for Bland- Altman plots. ICCs ranged from 0.736 to 0.917 at different time points, with the majority exceeding 0.800. The percentage of points within the 3-mmHg limit of agreement on Bland-Altman plots ranged from 72.7% to 97.0%, exceeding 80% in most cases. In conclusion, in patients with glaucoma or suspected glaucoma, IOP measurements obtained at each time point of the 24-hour DTC showed good or excellent reproducibility across the three curves performed

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unesp.br:11449/138410
Date10 June 2015
CreatorsHashimoto, Mitsuo [UNESP]
ContributorsUniversidade Estadual Paulista (UNESP), Rollo, Hamilton Almeida [UNESP], Silva, Maria Rosa Bet de Moraes [UNESP]
PublisherUniversidade Estadual Paulista (UNESP)
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/doctoralThesis
Format78 f.
SourceAleph, reponame:Repositório Institucional da UNESP, instname:Universidade Estadual Paulista, instacron:UNESP
Rightsinfo:eu-repo/semantics/openAccess
Relation-1, -1, -1

Page generated in 0.0026 seconds