Return to search

Metodologia para determinação de arsênio, antimônio e bismuto por espectrometria de emissão óptica com fonte de plasma acoplado indutivamente (ICPOES) e geração de hidretos aplicada à rochas

Made available in DSpace on 2014-06-11T19:26:13Z (GMT). No. of bitstreams: 0
Previous issue date: 2005-05-06Bitstream added on 2014-06-13T19:33:35Z : No. of bitstreams: 1
borges_em_me_rcla.pdf: 583445 bytes, checksum: a94bcee1df858747cf63f7c61d62429e (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / No presente trabalho são descritas as etapas para o desenvolvimento de uma metodologia para determinação de arsênio, antimônio e bismuto em materiais geológicos, utilizando gerador de hidretos acoplado ao ICPOES, proporcionando a determinação dos elementos de interesse em baixas concentrações. O método é sensível, por isso está sujeito a interferências, como as causadas por elementos presentes na matriz. Foram realizadas otimizações nos parâmetros operacionais e analíticos do equipamento, que visaram uma melhor sensibilidade e um método eficiente de solubilização completa de amostra de rocha, que permita a determinação dos elementos de interesse em baixas concentrações. Para a etapa de validação do método foram realizados diversos ataques com adições de padrão e testes com o uso de tiouréia e iodeto de potássio com ácido ascórbico em diferentes concentrações com o objetivo de minimizar possíveis interferências presentes na matriz. Os resultados finais foram obtidos através da solubilização de materiais de referência internacionais geológicos na determinação de arsênio, bismuto e antimônio e se mostraram satisfatórios. / In this study, the steps for the development of a methodology to the determination of arsenic, antimony and bismuth in geological materials, with the use of hydride generation and ICPOES are being described. The methodology is sensitive due to that, subject is bound to suffer interferences from matrix elements. Optimizations in operations and analyticals parameters were done in the equipment. They aimed a better sensitivite and an efficient method of complete dissolution techniques in a sample of rock, which permits the determination of the analyte in low concentrations. For the steps of methodology validation, many dissolutions were realized with the addition of standard and tests with the use of thiourea and KI and acid ascorbic in different concentrations with the objective of minimizing some interferences from matrix elements. The final results were obtained through dissolutions with international reference materials in the determination of arsenic, antimony and bismuth.

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unesp.br:11449/92858
Date06 May 2005
CreatorsBorges, Elisa Moura [UNESP]
ContributorsUniversidade Estadual Paulista (UNESP), Nardy, Antonio José Ranalli [UNESP]
PublisherUniversidade Estadual Paulista (UNESP)
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Formatviii, 73 f. : il., gráfs., tabs.
SourceAleph, reponame:Repositório Institucional da UNESP, instname:Universidade Estadual Paulista, instacron:UNESP
Rightsinfo:eu-repo/semantics/openAccess
Relation-1, -1

Page generated in 0.0023 seconds