Return to search

Águas de processo da REPLAN = qualidade e aplicação de processos oxidativos avançados / Process water from a Petroleum Refinery (REPLAN) : quality and application of advanced oxidation process

Orientadores: José Roberto Guimarães, Carlos Gomes da Nave Mendes / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-18T03:12:06Z (GMT). No. of bitstreams: 1
Gasparini_MirthysCozzett_M.pdf: 1574617 bytes, checksum: 879f212f74e005fca5974d6f943a790e (MD5)
Previous issue date: 2011 / Resumo: No presente trabalho foi realizada a caracterização de várias correntes de águas de processo da REPLAN (Refinaria de Paulínia), bem como a avaliação dos processos de fotólise (UV), peroxidação (H2O2), peroxidação assistida por radiação ultravioleta (H2O2/UV), reagente de Fenton (H2O2/Fe2+) e foto-Fenton (H2O2/Fe2+/UV) no tratamento de um dos efluentes, principalmente na degradação dos compostos orgânicos. Analisando-se os dados de caracterização dos diferentes efluentes foi possível sugerir alternativas de reuso no processo de refino, como também selecionar a corrente de água ácida retificada para aplicação dos processos físico-químicos de tratamento. A eficiência dos ensaios de tratabilidade foi baseada na redução da concentração do carbono orgânico dissolvido (COD). Dentre os processos estudados, os processos oxidativos avançados (POA) H2O2/UV e foto-Fenton apresentaram 95 % de eficiência após 150 minutos de ensaio. As condições ótimas foram obtidas na relação mássica COD: H2O2 de 1:7 para o processo peroxidação assistida por radiação UV, e de 1:5 e concentração de Fe2+ de 31 mg/L para o processo foto-Fenton. O efluente tratado pelo processo H2O2/UV poderia ser reutilizado como água de reposição no sistema de resfriamento, já que esta é responsável por 49 % do total de água utilizada na refinaria / Abstract: In the present study was performed the characterization of various process water from REPLAN (Paulínia Refinery) as well as an assessment of 5 processes to treat one of the effluents: photolysis (UV), peroxidation (H2O2), peroxidation assisted by ultraviolet radiation (H2O2/UV), Fenton reagent (H2O2/Fe2+) and photo-Fenton (H2O2/Fe2+/UV), in order to degrade the organic compounds. Effluents characterization results provided reuse possibilities in the process refining and also selected the stripped sour water stream for application of physical-chemical treatments. The processes efficiency was evaluated by the dissolved organic carbon (DOC) reduction. Among the processes studied, the advanced oxidation processes (AOPs) H2O2/UV and photo-Fenton reached 95 % efficiency after 150 minutes of reaction. The optimum conditions were obtained in a mass ratio COD: H2O2 of 1:7 for peroxidation assisted by UV radiation, and of 1:5 with 31 mg/L of Fe2+ for photo-Fenton. The effluent treated by AOP H2O2/UV could be reused as make-up water in cooling systems, since it is responsible for 49 % of the total water used in the refinery / Mestrado / Saneamento e Ambiente / Mestre em Engenharia Civil

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/257779
Date18 August 2018
CreatorsGasparini, Mirthys Cozzett
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Mendes, Carlos Gomes da Nave, 1958-, Guimarães, José Roberto, 1958-, Ferreira, Milena Guedes Maniero, Dezotti, Marcia Walquiria de Carvalho
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Engenharia Civil, Arquitetura e Urbanismo, Programa de Pós-Graduação em Engenharia Civil
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Format180 p. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0028 seconds