Return to search

Implementação de método de potência sonora em serra-mármore / Implementing a sound power method for testing noise on masonry saw

Orientador: Stelamaris Rolla Bertoli / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-25T10:59:34Z (GMT). No. of bitstreams: 1
Barbosa_AdrianoAurelioRibeiro_D.pdf: 5486627 bytes, checksum: fd9ac7f13185126d6aabd57ae00f989b (MD5)
Previous issue date: 2014 / Resumo: A poluição sonora e sua influência sobre o meio ambiente e a qualidade de vida das pessoas têm sido focos de várias pesquisas em diversas partes do mundo. Estudos apontam a construção civil como fator gerador de ruídos que incomodam a sociedade. A contribuição das máquinas e das ferramentas utilizadas nas obras tem influência direta neste processo. Os usos frequentes destes facilitadores estão entre as vertentes de melhoria de qualidade, racionalização dos processos e aplicação de inovações tecnológicas no setor. O estudo do comportamento e a caracterização dos ruídos ambientais nos canteiros de obras da construção civil, devido às operações com equipamentos elétricos, apresentam importância para o setor. A determinação do ruído gerado por máquinas, quando em contato com as superfícies de corte dos materiais de construção, contribui com as ações de controle do ruído em atividades desta natureza para fins ocupacionais e de conforto ambiental. A serra-mármore é uma máquina elétrica manual, portátil, largamente utilizada, na construção civil, para executar pequenos cortes e acabamentos em pisos, azulejos, telhas, tijolos e madeiras e destaca-se pela sua versatilidade, praticidade, leveza e ergonomia. O objetivo deste trabalho é propor um material de condição de carga padrão para implementação de método de determinação de potência sonora do ruído gerado por serra-mármore e estabelecer a incerteza de medição associada às operações. A metodologia utilizada para o estudo considerou os níveis de ruído gerados nas operações de corte em relação ao ruído do equipamento sem carga em concordância com a ISO 3744:2010, que especifica a determinação de níveis de potência sonora de ruído transmitido através do ar, por um método de engenharia, num campo livre sobre um plano refletor. Os resultados indicaram elevados níveis de ruído com a carga padrão proposta e diferentes materiais de construção em relação às atividades da serra-mármore sem carga. Os níveis globais de potência sonora obtidos nas operações chegaram a 110,1dB. A relação da condição do equipamento vazio e com carga apontam diferenças de até 10,0dB. Os resultados revelaram similaridade nas incertezas de medição nas operações de serra em diferentes condições de carga. Foi possível avaliar quantitativamente o nível de ruído gerado nas operações de corte, bem como propor um material de carga padrão para a determinação de níveis de potência sonora. Resultou em 4,3dB a incerteza de medição expandida nas operações da serra-mármore em campo aberto sobre um plano refletor. O estudo representa ainda uma contribuição na análise de ruído nas obras, considerando as dificuldades na obtenção de valores dos espectros sonoros nas operações de máquinas portáteis de construção civil na literatura, como a serra-mármore / Abstract: Worldwide, noise pollution and its influence on environment and quality of life have been studied. And so, such researches have pointed out the building construction as the main responsible for disturbing sounds today. In this sector, machinery and tools have direct influence on this process. Thus, the regular use of such tools are the main concern aiming quality improvement, streamlining processes and application of technological innovations in the industry. For this reason, the study and characterization of environmental noise behavior at construction sites (due to electrical equipment) is relevant for the sector, in order to contribute to noise control actions in construction activities aiming occupational purposes and environmental comfort. The masonry saw (circular saw for granite stone) is an electrical device, regularly used on building construction for cutting and shaping floors, tiles, bricks and woods and stands out for its versatility, practicality, lightness and ergonomics. Thus, the aim of our study is to design material of proper standard condition and measurement uncertainty associated with operations and measurements to implement the method for determining sound power of noise generated by masonry saw. The method applied in this study was comparing noise levels - generated by cutting operations - and the noise of the equipment without charge, according the ISO 3744:2010 (which specifies sound levels transmitted through the air, by a method of engineering, in a free field over a reflecting plane. Results have indicated high levels of noise with the proposed standard charge and different building materials in relation to the activities of the unloaded masonry saw. The overall sound power levels obtained from operations reached 110.1 dB. The ratio of unloaded and loaded device points to differences of up to 10.0 dB. Also, results have revealed a similarity in the measurement uncertainties in masonry saw operations on different load conditions. It was possible to quantitatively assess the noise level generated during cutting operations, so proposing a standard charge for determining sound power levels. Finally, the expanded measurement uncertainty has resulted in 4.3 dB of the masonry saw in an open field over a reflecting plane. Moreover, the study represents a great contribution for analyzing noise levels from the use of portable machinery on building construction, considering the difficulties in obtaining values of sound spectra in the literature / Doutorado / Arquitetura e Construção / Doutor em Engenharia Civil

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/257889
Date25 August 2018
CreatorsBarbosa, Adriano Aurelio Ribeiro, 1977-
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Bertoli, Stelamaris Rolla, 1958-, Bertoli, Stelamaris Rolla, Camarini, Gladis, Santos, José Maria Campos dos, Araujo, Marco Antonio Nabuco de, Gerges, Samir Nagi Yousri
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Engenharia Civil, Arquitetura e Urbanismo, Programa de Pós-Graduação em Engenharia Civil
Source SetsIBICT Brazilian ETDs
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/doctoralThesis
Format157 p. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0022 seconds