Plataforma eletromecanica para simulação de entorse de tornozelo e medida de tempo de resposta muscular atraves de eletromiografia / Eletromechanical platform for ankle sprain simulation and measure of the muscle reaction time by electromyography

Orientador: Jose Antonio Siqueira Dias / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-08-13T17:14:06Z (GMT). No. of bitstreams: 1
Pfrimer_FelipeWalterDafico_M.pdf: 6672508 bytes, checksum: 39acf3b2b29bc9b6447f7b7c9e599b28 (MD5)
Previous issue date: 2009 / Resumo: Neste trabalho é apresentado o projeto de uma plataforma eletromecânica que simula um movimento de entorse de tornozelo para que, dessa maneira, seja possível determinar o tempo de resposta eletromiográfica dos músculos do tornozelo. Foi apresentada e desenvolvida uma nova técnica de medida do tempo inicial do movimento do tornozelo (quando a plataforma inicia o movimento de queda). Esta técnica usa um potenciômetro de precisão para medir a posição angular da plataforma que está em queda em função do tempo. Foram projetadas duas placas de aquisição. A primeira placa, que tem a função de medir a reação muscular do tornozelo, é basicamente um eletromiógrafo. A segunda é capaz de medir a proporção de peso sobre um dos pés do paciente e o ângulo de torção. Ambas comunicam-se com um computador, através de portas USB, onde um programa, desenvolvido em Labview, especialmente criado para o sistema, recebe e interpreta os dados dos sensores. O sistema foi testado com indivíduos que não apresentavam histórico de entorse de tornozelo, tendo sido obtidos ótimos resultados. O eletromiógrafo desenvolvido como parte da plataforma pode ser usado separadamente, em qualquer outra aplicação onde seja desejado realizar medidas de eletromiografia. / Abstract: This work presents the design of a electromechanical platform that simulates an ankle sprain movement in order to measure the electromyographic time response of the ankle muscles. A new technique was employed to measure the initial time of the ankle movement, when the platform starts to fall. This technique uses a precision potentiometer to measure the angular position of the falling platform, so that all mechanical errors which are inherent to the system and cause errors in the evaluation of the initial time of the movement can be totally eliminated. Two data-acquisition boards were designed and implemented. The first board measures the reaction of the ankle muscles, and is basically an electromyograph. The second board is measures both the weight on each feet of the patient, and the angular position of the falling platform as a function of the time. Both signal processing boards communicate with a computer through USB ports, where a software especially created for the system, developed in LabVIEW, receives and calculates several parameters from the data acquired from sensors. The system was tested in subjects without ankle sprain history, presenting excellent results. The electromyograph, developed as a part of the platform, can be used in stand-alone mode, in any application where electromyographic measurements are necessary. / Mestrado / Eletrônica, Microeletrônica e Optoeletrônica / Mestre em Engenharia Elétrica

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/259313
Date03 June 2009
CreatorsPfrimer, Felipe Walter Dafico, 1984-
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Dias, José Antonio Siqueira, 1954-, Serran, Nivaldo Vicençotto, Iano, Yuzo
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Engenharia Elétrica e de Computação, Programa de Pós-Graduação em Engenharia Elétrica
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Format60 f. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess