Return to search

Modelagem e analise de reatores cataliticos de leito fixo / Modelling and analysis of fixed bed catalytic reactor

Orientador: Rubens Maciel Filho / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Quimica / Made available in DSpace on 2018-08-15T04:17:09Z (GMT). No. of bitstreams: 1
Morais_EdvaldoRodrigode_D.pdf: 6747685 bytes, checksum: c02b586c7235aff32140ce7dcd3c8e2c (MD5)
Previous issue date: 2007 / Resumo: Em reações altamente exotérmicas, uma das principais características dos reatores catalíticos de leito fixo está relacionada ao surgimento do ponto quente ou hot-spot, sendo sua prevenção de fundamental importância para o bom desempenho do reator, uma vez que ele pode levar ao aumento excessivo da temperatura no leito catalítico, o que poderia resultar em possíveis condições de instabilidade. Um fator importante para estabelecer limites de estabilidade e que, portanto, deve ser considerado dentro do projeto de reatores catalíticos de leito fixo, está relacionado à escolha da configuração de escoamento do fluido refrigerante. Desta forma, duas novas configurações de escoamento para o fluido refrigerante, empregando simultaneamente as configurações convencionais co-corrente e contra-corrente, são propostas. O objetivo é explorar e analisar a influência de diferentes configurações de refrigeração sobre o comportamento de reatores catalíticos de leito fixo monotubulares e multitubulares através de sua modelagem e simulação, reduzindo assim os efeitos do ponto-quente sobre o comportamento estacionário do reator. O emprego de modelos multitubulares é essencial quando existe a necessidade de se considerar detalhadamente todos os aspectos relacionados ao projeto mecânico do reator e também onde as interações existentes entre os tubos forem importantes. Dentre as configurações de refrigeração empregadas estão as formas convencionais, denominadas co-corrente e contra-corrente, e também as configurações mistas, que utilizam ambas as formas convencionais simultaneamente. Como caso de estudo é considerada a reação de oxidação parcial do benzeno em anidrido maleico sobre catalisador de pentóxido de vanádio (V2O5), a qual apresenta equações de taxa complexas e é altamente exotérmica, e representa uma importante classe dentro dos processos industriais. Para tanto foram desenvolvidos softwares escritos em FORTRAN 90 capazes de permitir ao usuário o estudo de diversas configurações de refrigeração e diferentes condições de operação e de projeto, tanto para o reator monotubular quanto multitubular, sendo ainda compatíveis com outras reações de interesse industrial, o que torna os procedimentos e a metodologia desenvolvidos de uso geral / Abstract: One of the main characteristics of fixed bed catalytic reactors when high exothermic reactions are carried out is the presence of the hot-spot. Prevention of hot-spot appearance is extremely important for good reactor performance, since it can lead to an excessive increase in reactor bed temperature, which could result in unstable conditions. An important factor to establish stability limits and, therefore, to be considered during the fixed bed catalytic reactor design is the choice of the coolant flow pattern. In doing so, two new coolant flow patterns are purposed using both co-current and counter-current conventional configurations simultaneously. The main objective is to explore and analyze the influence of different cooling modes on the monotubular and multitubular fixed bed catalytic reactors behavior through their modeling and simulation, reducing in this way the effects of the hot-spot on the steady state reactor behavior. The use of multitubular models is essential when there is a need to consider in detail all aspects related to the reactor mechanical design and also where the interactions between tubes are important. Among the cooling modes used are the conventional flow patterns, called co-current and counter-current, and also the mixed flow patterns, which use both conventional forms simultaneously. As a case study, the reaction of partial oxidation of benzene to maleic anhydride over a vanadium pentoxide catalyst (V2O5) is considered, which presents complex rate equations, is highly exothermic, and represent an important class of industrial processes. Bearing this in mind, FORTRAN 90 softwares that permit the user to study different cooling modes and various operational and design conditions for both mono-tubular and multitubular reactors were developed. These softwares are compatible with other reactions of industrial interest, which makes the procedures and methodology developed for general use / Doutorado / Desenvolvimento de Processos Químicos / Doutor em Engenharia Química

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/267109
Date15 August 2018
CreatorsMorais, Edvaldo Rodrigo de
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Maciel Filho, Rubens, 1958-, Boldrini, José Luiz, Meyer, João Frederico da Costa Azevedo, Melo, Delba Nise Cosme, Pinto, Jefferson Ferreira
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Engenharia Química, Programa de Pós-Graduação em Engenharia Química
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/doctoralThesis
Format179 p. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0019 seconds