Return to search

Avaliação in vitro da alteração de peso e rugosidade superficial de reembasadores resilientes temporarios e resistencia de uniao com a resina acrilica para microondas quando submetidos a agente quimico de limpeza de proteses

Orientadores: Renata Cunha Matheus Rodrigues-Garcia, Altair A. Del Bel Cury. / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-27T22:45:50Z (GMT). No. of bitstreams: 1
TorresLeon_BlancaLiliana_M.pdf: 3306981 bytes, checksum: 5790c74625cbc5393bc41e340026d9e4 (MD5)
Previous issue date: 2001 / Resumo: Os reembasadores resilientes apresentam uma ampla utilização na prática clínica. O objetivo deste estudo foi avaliar a alteração de peso, rugosidade superficial e resistência de união com a resina acrílica de microondas, de reembasadores resilientes temporários, submetidos a um agente de limpeza de próteses. Amostras de resina (Onda-Cryl) foram divididas em 04 grupos, de acordo com o material reembasador recebido e tratamento de imersão: Gl) reembasadas com Coe-Soft e tratadas com Polident; G2) reembasadas com Coe-Soft e imersas em água (controle); G3) reembasadas com Dentusoft e tratadas com Polident e G4) reembasadas com Dentusoft e imersas em água (controle). Para o teste de resistência de união foram confeccionadas 48 corpos-de-prova para cada grupo; e para alteração de peso e rugosidade superficial foram utilizados 10 corpos-de-prova. As amostras foram mantidas em saliva artificial por 15 dias à 37°C, imersas uma vez ao dia em Polident ou água e avaliadas em 04 tempos: imediatamente após a confecção, após 24 horas, 7 e 15 dias. Os resultados foram submetidos a análise de variância e as médias foram comparadas pelo teste de Tukey a nível de 5 % de significância. Os resultados mostraram que: A) para alteração de peso (g), houve diferença significante entre os reembasadores avaliados às 24 horas (Coe-Soft:0,66:1:0,1O e Dentusoft: 1,05:1:0, 10). Houve diminuição da alteração de peso às 24 horas e 7 dias, mas não aos 15 dias. Com relação aos tratamentos e tempos avaliados, houve diferença significante entre os tratamentos no 7° dia (Água: 0,25:1:0,13 e Polident: 0,46:1:0,13) e 15° dia (Água:-0,2:1:0,061 e Polident: 0,05:1:0,06). Para o Polident, houve diminuição na alteração do peso com o decorrer o tempo (Oh:0,87:1:0,19; 7dias:0,46:1:0,13 e 15 dias:0,05:1:0,06), enquanto que para a água, houve decréscimo às 24 horas (0,84:1:0,25) e 7 dias (0,25:1:0,13) mas não aos 15 dias (-0,2:1:0,061); B) para rugosidade superficial (11m), houve diferença significativa entre os tratamentos no 7° dia (Água: 3,88:1:0,56 e Polident: 3,31:1:0,47) e 15° dia (Água: 4,65:1:0,83 e Polident: 3,61:1:0,51), mas não às O e 24 horas. Para o tratamento com Polident, houve diferenças significativas entre os tempos de 15 dias (3,61:1:0,51) e 24 horas (3,05:1:0,60), enquanto que com água, a rugosidade superficial aos 15 dias (4,65:1:0,83) foi significativamente maior comparada com os demais tempos (Oh: 3,38:1:0,41; 24h:3,08:1:0,63; 7dias: 3,88:1:0,56); e C) para a resistência de união (MPa) houve diferença significante entre os reembasadores ao serem imersos em água (Coe-Soft: 3,57:1:1,35 e Dentusoft: 3,26:1: 1,32). Em relação aos tratamentos, não houve diferença estatística significante nos diferentes tempos estudados. Os resultados da avaliação da interface de união reembasador-resina, demostraram que a maior porcentagem de falhas observadas foram de tipo coesivas (Coe-Soft: 76,04% e Dentusoft: 82,29 %). Conclui-se que o Polident acarretou maior alteração de peso entre os reembasadores estudados. A rugosidade superficial destes materiais foi maior na água e a resistência de união não foi alterada com os tratamentos / Abstract: Soft lining resilients presents some properties that allows the rehabilitation of damaged soft tissues. The purpose of this study was to evaluate changes in weight, surface roughness and bond strenght of soft lining resilients when submitted to cleaning chemical agents for removable prosthesis. Samples of Onda Cyl resin, where randomly divided into 4 groups, acoording to the soft lining resilient material received and the immersion treatment: G 1) relined with CoeSoft and treated with Polident; G2) relined with CoeSoft and treated with water (control group); G3) relined with Dentusoft and treated with Polident and G4) relined with Dentusoft and treated with water (control group). AlI samples remained in artificial saliva for 15 days at 37°, and were immersed once a day in Polident or water. Evaluations were made immediately after treatment and 24 hour, 7 days and 15 days later. The results showed: A) when analysing weight changes (g) related significant difference between soft lining resilients at 24 hours (CoeSoft: 0,66:1::0,10 and Dentusoft: 1,05:1::0,10) There was decrease in weight at 24 hours and 7 days, but not after 15 days. Regarding to treatment and times, there was significant differences between 7 days (Water:0,25:1::0,13 and Polident: 0,46:1::0,13) and 15 days (Water: -0,2:1::0,061 and Polident: 0,05:1::0,06). There was a decrease in weight loss related to time (Oh: O, 87:1::0, 19; 7days: 0,46:1::0, 13;15days: 0,05:1::0,06) when using Polident, while there was a decrease in weight loss after 24 hours (0,84:1::0,25) and 7 days (0,25:1::0,13) but not after 15 days (-0,2 :1::0,061) when using water. B) when analysing the surface roughness (_m) related to the agent used and periods of time, there was a significant difference between treatments after 7 (Water:3,88:1::0,56 and Polident: 3,31:1::0,47) and 15 days (Water:4,65:1::0,83 and Polident: 3,61:1::0,51), but not after O and 24 hours. There was a significant difference between 15 days (3,6l:i::0,51)and 24 hours (3,05:f:0,60) when Polident was used, while surface roughness after 15 days (4,65:f:0,83) were significantly higher when compared to the other periods (Oh:3,38:f:0,41; 24h:3,08:f:0,63; 7days:3,88:f:0,56) in samples treated with water and C) when analyzing bond strenght (MPa) related to the soft lining resilients and treatments, there was a significant difference when the samples that were immersed in water (CoeSoft:3,57:f:1,35 and Dentusoft:3,26:f:1,32). When analysing periods of time and soft lining resilients, there was no statistical differences of the treatments. The results in bond strenght between resin and soft lining, have a lot percentage that failures were cohesives (Coe-Soft: 76,04% e Dentusoft: 82,29 %). Conclude that Polident led to greater weight loss of the soft lining resilients analysed in this study. The surface roughness of the materials were greater in water than in Polident, and none of the treatments changed the bond strenght of the materials / Mestrado / Protese Dental / Mestre em Clínica Odontológica

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/288668
Date19 April 2001
CreatorsTorres Leon, Blanca Liliana
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Del Bel Cury, Altair Antoninha, 1948-, Rodrigues-Garcia, Renata Cunha Matheus, 1964-, Boscarioli, Ana Paula Teixeira de, Goes, Mario Fernando de
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Odontologia de Piracicaba, Programa de Pós-Graduação em Clínica Odontológica
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Format118p. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0023 seconds