Return to search

Tratamento de fraturas de mandíbulas atróficas : estudo epidemiológico, mecânico e análises de elementos finitos / Atrophic mandible fractures traetment : epidemiological study, mechanical and finite element analysis

Orientador: Luciana Asprino / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-20T21:58:02Z (GMT). No. of bitstreams: 1
Freire_SimeiAndredaSilvaRodrigues_D.pdf: 1346412 bytes, checksum: 35f4f1e8f5181ebc1bf60768170c3f2c (MD5)
Previous issue date: 2012 / Resumo: O objetivo desse trabalho foi avaliar a epidemiologia e características do tratamento de fraturas de mandíbula atrófica; comparar a resistência mecânica e a distribuição de tensões de três técnicas de fixação interna aplicadas em fraturas de mandíbulas atróficas. CAPÍTULO I: Dados foram coletados de pacientes vítimas de fraturas em mandíbulas atróficas em um período de dez anos (1999-2009). Os dados analisados continham informações demográficas e socioeconômicas, etiologia dos traumas, diagnóstico, tipos de traumas, deslocamento das fraturas, o método de fixação utilizado, região das fraturas, traumas associados, tempo decorrido entre o trauma e tratamento. A principal causa das fraturas em mandíbulas atróficas foi a queda da própria altura, acometendo principalmente pacientes do gênero masculino desempregados. A faixa etária mais acometida foi a de trinta a sessenta anos ocorrendo predominantemente fraturas bilaterais na região de corpo mandibular. CAPÍTULO II: Avaliou-se a resistência, in vitro, por meio de testes de carregamento linear a fixação de fraturas de mandíbulas atróficas com defeito de continuidade por meio de três sistemas de fixação. Foram utilizadas réplicas de mandíbulas humanas atróficas de poliuretano submetidas a simulação de fratura com defeito de continuidade de 15mm em corpo direito, fixadas pelos seguintes sistemas: Grupo 1 - sistema 2,4mm conventional, Grupo 2 - sistema 2,4 mm com travamento e Grupo 3 - sistema 2,0mm com travamento. Pelos resultados obtidos o sistema com travamento aumentou a resistência da fixação pela melhor e mais favorável distribuição de cargas, os sistemas 2,4mm de fixação interna estável testados apresentaram adequada resistência mecânica para tratamento de fraturas de mandíbulas atróficas com defeito de continuidade. CAPÍTULO III: Avaliou-se, in sílico, pelo método de elementos finitos a fixação de fraturas de mandíbulas atróficas por meio de três sistemas de fixação submetidas a testes de carregamento linear. Os modelos criados em elementos finitos de fratura de mandíbula atrófica foram fixados pelos seguintes sistemas, sistema 2,4mm convencional, sistema 2,4mm com travamento e sistema 2,0mm com travamento. Pelos resultados obtidos o sistema 2,4mm convencional demonstrou suportar toda carga aplicada nesta simulação, os sistemas com travamento apresentaram dissipação das tensões para região anterior e posterior da mandíbula e no sistema de fixação convencional as tensões se localizaram na porção entre os furos do sistema de fixação assim como no sistema com travamento, porém este ainda apresentou dissipação para os parafusos, com concentração crescente para região apical dos parafusos próximos a simulação do traço de fratura / Abstract: The aim of this study was to evaluate the epidemiology and treatment characteristics of atrophic mandibular fractures; to compare the mechanical strength and stress distribution of three internal fixation techniques applied in atrophic mandibles fractures treatment. CHAPTER I: Data were collected from patients suffering from atrophic mandibles fractures in a period of ten years (1999-2009). The data analyzed contained demographic and socioeconomic characteristics, etiology of trauma, diagnosis, types of trauma, displacement of the fractures, the region of fracture, associated trauma, time elapsed between trauma and treatment. The main cause of fractures in atrophic mandibles was fall accidents, affecting mainly male unemployed patients. The age group most affected was between thirty to sixty years occurring bilateral fractures predominantly in the mandibular body region. CHAPTER II: Resistance was evaluated in vitro by linear loading test in the atrophic mandible fracture simulation with continuity defect by three stable internal fixation systems. It was used replicas of human atrophic polyurethane mandible subjected to simulated fracture defect continuity of 15mm in right body region, fixed by the following systems: Group 1 - 2.4mm conventional system, Group 2 - 2.4 mm locking system and Group 3 - 2.0mm locking system. The results obtained with the locking system increased the resistance setting for the better and more favorable load distribution, the 2.4mm stable internal fixation systems tested had adequate mechanical strength for the treatment of fractures of atrophic mandibles with continuity defects. CHAPTER III: It was evaluated ,in silico, by the method of finite elements with linear force three stable internal fixation systems for the treatment of atrophic mandible fractures. The finite element models created in the atrophic mandible fracture were fixed by the following systems, the conventional system 2.4mm, 2.4mm locking system and 2.0mm locking system. The results obtained demonstrated that the locking system increased the resistance by a favorable and better distribution of the stresses during the loading test when applied in atrophic mandible fractures with continuity defects. The three internal fixation systems tested in this study showed adequate mechanical efficiency to be applied in atrophic mandible fractures with continuity defects treatment / Doutorado / Cirurgia e Traumatologia Buco-Maxilo-Faciais / Doutor em Clínica Odontológica

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/289615
Date07 March 2012
CreatorsFreire, Simei André da Silva Rodrigues, 1981-
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Asprino, Luciana, 1974-, Sverzut, Alexander Tadeu, Moura, Walter Leal de, Barbosa, José Ricardo de Albergaria, Noritomi, Pedro Yoshito
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Odontologia de Piracicaba, Programa de Pós-Graduação em Clínica Odontológica
Source SetsIBICT Brazilian ETDs
LanguageInglês
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/doctoralThesis
Format65 f. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0032 seconds