Return to search

Avaliação da precisão de metodos utilizados na determinação do desajuste das bases de protese total

Orientadores : Saide Sarckis Domitti, Simonides Consani / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-28T03:49:16Z (GMT). No. of bitstreams: 1
Hayacibara_RobertoMasayuki_M.pdf: 2978473 bytes, checksum: deedb6107fb0c5076942b5ad9d4ad29b (MD5)
Previous issue date: 2001 / Resumo: O objetivo deste trabalho foi avaliar a precisão de dois métodos utilizados na determinação do desajuste das bases de prótese total, confeccionadas com resina acrílica ativada termicamente. Foram obtidos 10 modelos em gesso pedra a partir de um molde de silicone representando uma arcada superior desdentada normal. Sobre os modelos foram confeccionadas as bases de pro:va, incluídas em mufla pela técnica de rotina com polimerização da resina acrílica em banho de água aquecida a 74 :f:2°C por 9 horas. Após esfriamento das muflas em temperatura ambiente, as bases de prótese foram removidas, limpas e acabadas. Em cada conjunto modelo-base de prótese foram demarcadas três linhas transversais (anterior, médio e posterior) e em cada linha foram marcados 5 pontos (fundo de sulco vestibular esquerdo e direito, crista do rebordo esquerdo e direito e linha mediana) onde foram feitas as mensurações. Os métodos estudados na verificação da desadaptação foram: A- interposição de silicona por condensação entre a base e o modelo e a aferição com paquímetro digital modificado; B- após fixação da base no modelo com adesivo, três cortes transversais foram efetuados e as mensurações feitas com microscópio comparador linear. Os dados foram submetidos a Análise de Variância e ao teste de Tukey (5% de significância) que mostraram que o método da medição linear com microscópio comparador foi mais preciso que o método da interposição de silicona, revelando desadaptação com valores estatisticamente menor e significantes, quando foram considerados os fatores método, região e pontos estudados / Abstract: The aim of this study was to evaluate the accuracy of two measurement methods used for the detennination of the adaptation and stability of denture bases made of thermopolymerizing acrilic resin. One rubber mold was used to produce ten identical maxillary edentulous casts in dental stone. Ten denture bases were included into flasks and processed by the conventional method of polymerization (thennostatically controlled water bath for 9 hours at 74 :t2°C) above the dental casts. After cooling at room temperature, the denture bases were removed ITom the flasks, cleaned and trimmed. In each cast with the denture in place, three transversallines settled in the anterior, medial and posterior regions were demarcated, and in each line the space between the base and the cast was measured at 5 reference points (left and right sulcus depth, left and right ridge crest and midpalatal points). Two methods were used: A- interposition of an impression material (silicone rubber) and measurement of its thickness using a modified caliper; B- after fixation of the bases into the casts with adhesive, they were transversely seccioned at the reference lines and read in a linear comparator microscope. AlI data were analysed by ANOV A and Tukey test (5%), and it was concluded that the analyses done by using microscope were more accurate than the interposition of the impression material, revealing for the former method, statistically significant low values, considering methods, regions and points studied. / Mestrado / Protese Dental / Mestre em Clínica Odontológica

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/289953
Date19 April 2001
CreatorsHayacibara, Roberto Masayuki
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Consani, Simonides, 1939-, Domitti, Saide Sarckis, 1932-2016, Mesquita, Marcelo Ferraz, Filho, João Arioli
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Odontologia de Piracicaba, Programa de Pós-Graduação em Clínica Odontológica
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Format106p. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0188 seconds