Return to search

Influencia da reutilização do hidrocoloide reversivel na alteração dimensional linear de modelos de revestimento utilizados no processo de fundição de proteses parciais removiveis

Orientador: Celia Marisa Rizzatti-Barbosa / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-27T13:33:14Z (GMT). No. of bitstreams: 1
Arana_AndreRobertoSetten_D.pdf: 3165588 bytes, checksum: 8d2c0adb758f1b78f8d140e623a59e5a (MD5)
Previous issue date: 2000 / Resumo: O objetivo deste trabalho foi avaliar a alteração dimensional linear de modelos revestimentos obtidos após vários ciclos de reutilização do hidrocolóide reversível (Duplitarc 50 MX - Citarc tecnologia de minérios). O modelo metálico utilizado tinha 4 marcações, A, B, C e O, dispostas nas regiões de molares e caninos em ambos os lados da arcada, de forma que quando unidas formassem a figura de um polígono irregular e permitissem a mensuração linear das distâncias AB, BC, CO, DA, AC e BO. A partir deste modelo metálico, foram confeccionados 10 modelos de gesso especial, duplicados sempre com o mesmo HR fundido em fomo de microondas. A 57.C o material era vertido sobre o modelo de gesso, e após sua geleificação, o molde era preenchido com revestimento de silicato de etila. Após a geleificação dos modelos de silicato de etila, estes eram desidratados a 180. - 200.C por 30 minutos e imersos no banho de cera de carnaúba liquefeita. Com esta metodologia foram confeccionadas 10 amostras para cada grupo estudado (G1, G2, G3, G4 e G5), após respectivamente 1, 5, 10, 15 e 20 reciclagens de fluidificação-geleificação. Foi utilizado um microscópio mensurador linear (Ernst Leitz Wetzlar - 3: 1 - Germany), para que as avaliações fossem realizadas. Após a coleta dos dados, os mesmos foram analisados pelo teste de OUNNETT'S, ao nível de 5% de significância. Os resultados mostraram que as distâncias que diferiram foram SC e CD, apenas entre os grupos G5 e G1, respectivamente com 0,0969 mm e 0,0914 milímetros de diferença entre suas médias. Os resultados permitiram concluir que mesmo apresentando diferenças estatísticas após 20 ciclos, estas foram irrelevantes laboratorialmente para o fim que o hidrocolóide é proposto, não havendo após 20 ciclos de reutilização, grandes alterações dimensionais / Abstract: One of the critical steps for the making of removable partial prostheses (RPP), it is the duplication of the work model in coating model by means of the reversible hydrocolloid. The objective of this work was evaluate lineal dimensional alteration of refractory models obtained after several cycles of heating of reversible hydrocolloid. Starting from a metallic model with points defined for lineal mensuration, were made 10 models of special gypsum, always duplicated with same reversible hydrocolloid melted in microwave's oven. At the 52°C the material was fIowed on the model of gypsum, and after its geleification, the mold was filled with coating of ethyla silicate. After the crystallization of the models of ethyla silicate, these were dehydrated at 180 - 2000C for 30 minutes and immerged in the bathing of liquefied wax. With this methodology were made samples of the 5 groups (G1, G2, G3, G4 and G5), afier respectively 1, 5, 10, 15 and 20 fluidification-geleification cycles. It was used a compared microscope lineal so that the mensurations were made. After the collection of the data the same ones were analyzed by the DUNNETT'S test with the significance leveI set on 5%. The results showed that just the distances SC with 0.0969 mm and CD with 0.0914 mm of difference between the averages respectively, presented differences statistical/y significant, only when compared between G5 (20 cycles reused) and G1 (1 cycle reused) for SC and CD respectively. The results allowed to conclude that reversible hydrocolloid recast in microwave¿s oven did not promote abrupt dimensional alterations where the samples presented dimensional stability after 20 cycles reused. / Doutorado / Protese Dental / Doutor em Clínica Odontológica

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/290535
Date04 December 2000
CreatorsArana, Andre Roberto Setten
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Rizzatti-Barbosa, Celia Marisa, 1957-, Marchese, Marco Polo, Neisser, Maximiliano Piero
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Odontologia de Piracicaba, Programa de Pós-Graduação em Clínica Odontológica
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/doctoralThesis
Format103p. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0114 seconds