Return to search

Microscopias ópticas de processos coerentes / Optical microscopies of coherent processes

Orientador: Carlos Lenz César / Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Física Gleb Wataghin / Made available in DSpace on 2018-09-01T03:43:43Z (GMT). No. of bitstreams: 1
Pelegati_VitorBianchin_D.pdf: 6822381 bytes, checksum: 86749ce34dc184aeb7ed4b4ee47d70b3 (MD5)
Previous issue date: 2016 / Resumo: Técnicas de microscopias ópticas são as principais ferramentas capazes de observar células e tecidos biológicos em tempo real e com mínimo dano. Essa área foi revolucionada recentemente através das microscopias confocais de varredura a laser e as microscopias de óptica não linear, naturalmente confocais. Entre os processos não lineares temos, a fluorescência excitada por dois ou mais fótons, geração de segundo harmônico [Second Harmonic Generation - SHG] e terceiro harmônico [Third Harmonic Generation - THG]. SHG e THG são técnicas de óptica não linear coerentes, não necessitam de marcadores exógenos e permitem reconstrução de imagens em três dimensões com resolução espacial subcelular. As técnicas de fluorescência permitem visualizar estruturas específicas no espaço, mas não permitem discriminar as substâncias químicas nas estruturas celulares, e as técnicas de SHG e THG não possuem especificidade química. Espectroscopia Raman possui especificidade química através das propriedades vibracionais das moléculas e pode ser usada como mecanismo de contraste na aquisição de imagens. Comparada com a espectroscopia/microscopia infravermelho, a microscopia Raman traz a informação das vibrações moleculares do infravermelho para o visível, eliminando os problemas da baixa resolução espacial e opacidade das amostras. Entretanto a baixa sensibilidade dessa técnica implica em tempos de aquisição de imagens muito longos, da ordem de horas, inviabilizando acompanhar a dinâmica de processos celulares em tempo real. Como solução para essa baixa sensibilidade do espalhamento Raman espontâneo, surgiu a microscopia por espalhamento Raman Coerente anti-Stokes [Coherent Anti-Stokes Raman Scattering - CARS]. Comparado com Raman espontâneo, a microscopia CARS representa aumento de 4 a 5 ordens de grandeza na sensitividade da técnica, diminuindo os tempos de aquisição ao ponto de viabilizar a aquisição em taxas de vídeos (mais rápido do que 30 quadros por segundo) e estudos em tempo real. Essa tese é dedicada ao estudo experimental e teórico, assim como de algumas aplicações, das técnicas de óptica não linear, com destaque para processos de óptica não linear coerentes. Apresentamos de forma detalhada três sistemas experimentais para a aquisição de imagens de Raman coerente e um sistema integrado com várias técnicas de óptica não linear. Mostramos as primeiras imagens de CARS realizadas no Brasil. Além do CARS convencional, trabalhamos com outra técnica de CARS de ordem mais alta, o CARS cascata [cascade CARS - CCARS], e, no melhor do nosso conhecimento, apresentamos as primeiras imagens internacionais obtidas com essa metodologia. CCARS aumenta o contraste da técnica CARS, diminuindo o fundo não ressonante, um problema que aflige a comunidade científica dedicada ao uso dessa técnica. Além da diminuição do fundo não ressonante, a emissão do CCARS acontece em um comprimento de onda diferente de qualquer outro efeito não linear coerente, significando um acréscimo de complexidade mínimo para sua detecção quando comparado com o CARS. Por último mostramos algumas aplicações realizadas com o sistema experimental desenvolvido para integrar diversas modalidades ópticas em paralelo, especialmente da geração de harmônicos com a fluorescência excitada por dois fótons e suas variantes, como microscopia de tempo de vida de fluorescência (Fluorescence Lifetime Imaging ¿ FLIM) / Abstract: Optical microscopies techniques are the main tools capable of observing cell and biological tissues in real time and with minimum damage. This area have recently been revolutionized by confocal laser scanning microscopies and non-linear microscopies, naturally confocal. Among the non-linear process we have, the two or more photons excited fluorescence, second harmonic generation [SHG] and third harmonic generation [THG]. SHG and THG are coherent nonlinear techniques, they do not require exogenous markers and allow three dimension imaging reconstruction with subcellular resolution. The fluorescence techniques allow visualizing specific structures in space, but do not allow discriminating the chemical substances in cellular structures, SHG and THG techniques do not have chemical specificity. Raman spectroscopy has chemical specificity through the vibrational properties of the molecules and can be used as a contrast mechanism for imaging acquisition. Compared to infrared spectroscopy/microscopy, Raman microscopy brings information about molecular vibration from infrared to visible, eliminating the low resolution and sample opacity problems. However, this technique low sensibility implies in very long imaging acquisition times, order of hours, making it not viable for following cellular process dynamics in real time. As an answer for the spontaneous Raman scattering low sensibility, the coherent anti-Stokes Raman scattering [CARS] emerged. Compared to spontaneous Raman, CARS microscopy presents an increase of 4 to 5 orders of magnitude in the sensitivity of the technique, lowering the acquisition times to the point of making video acquisition (faster than 30 frames per second) and real time studies possible. This thesis is dedicated to the experimental and theoretical study, as well as some applications, of the non-linear techniques, with emphasis on coherent non-linear optical processes. We present in detailed form three experimental systems for the acquisition of coherent Raman images, and a system with the integration of various non-linear techniques. We show the first CARS images acquired in Brazil. In addition to conventional CARS, we worked with other higher order CARS technique, the cascade CARS [CCARS], and, in the best of our knowledge, we present the first international image acquired with this methodology. CCARS increases the contrast from CARS technique, decreasing the non-resonant background, a problem that afflicts the scientific community dedicated to the use of this technique. Besides the decrease of the non-resonant background, the CCARS emission occurs in a different wavelength from any other non-linear coherent effect, meaning a minimum complexity increase for its detection when compared with CARS. Finally we show some applications performed with the experimental system developed to integrate several optical modalities in parallel, especially the generation of harmonics with two photons excitation fluorescence and their variants such as Fluorescence Lifetime Imaging [FLIM] / Doutorado / Física / Doutor em Ciências / 830406/2010 / CAPES

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/321828
Date20 December 2016
CreatorsPelegati, Vitor Bianchin, 1982-
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, César, Carlos Lenz, 1955-, Lima, Marco Aurélio Pinheiro, Roversi, José Antonio, Martin, Airton Abrahão, Zezell, Denize Maria
Publisher[s.n.], Universidade Estadual de Campinas. Instituto de Física Gleb Wataghin, Programa de Pós-Graduação em Física
Source SetsIBICT Brazilian ETDs
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/doctoralThesis
Format165 f. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0035 seconds