Estudo do equilíbrio de fases em sistemas aquosos contendo albumina de soro bovino e polietileno glicol. / Phase equilibrium study in aqueous systems containing bovine serum albumin and polyethylene glycol.

No presente trabalho estudou-se o equilíbrio de fases em sistemas aquosos contendo albumina do plasma bovino (BSA) e polietileno glicol (PEG) com tamanhos médios de cadeia 2000, 4000, 6000 e 10000, para valores de pH iguais a 4,0, 5,0 e 6,0, na temperatura de 25ºC. Pôde-se observar que o diagrama de fases é dependente do pH e do tamanho da cadeia. Conforme a região do diagrama, observaram-se sistemas que apresentaram características de equilíbrio sólido-líquido (ESL) e de equilíbrio líquido-líquido (ELL), além de sistemas presumivelmente metaestáveis que apresentam uma transição dos dois comportamentos, cujas concentrações de PEG são intermediárias em relação aos sistemas que apresentam puramente o ELL ou o ELS. Mediante a interpretação dos dados experimentais e a análise a partir da equação de Flory-Huggins, verificou-se a dependência direta entre o tamanho médio de cadeia polimérica e a formação do ELS. Os resultados sugerem que os grupos hidroxila terminais das moléculas de PEG interagem com as moléculas de BSA, alterando a conformação das últimas de tal modo que o coeficiente de interação BSA-H2O (oriundo da equação de Flory-Huggins) também se altera. Como o parâmetro de maior influência na atividade da proteína em solução é justamente o coeficiente de interação BSA-H2O, pequenas alterações geram uma grande mudança no cálculo desta atividade sendo portanto o principal fator a afetar a estado de equilíbrio. / The phase equilibrium in aqueous systems containing bovine serum albumin (BSA) and polyethylene glycol (PEG) with average molar mass values of 2000, 4000, 6000 and 10000 was studied in this work. All experiments were carried out at 25ºC, and the pH was varied within the values 4,0, 5,0 and 6,0. It was observed that the phase diagram depends on the pH and on polymer chain average size. According to the composition of the systems, not only solid-liquid (SLE) and liquid-liquid (LLE) equilibrium were observed, but also possible metastable systems with transition characteristics, whose PEG concentrations are intermediate to the purely SLE or LLE systems. Following the experimental data interpretation and the analysis of the Flory-Huggins equation, it was observed a direct relationship between the polymeric average size and the formation of SLE. The results imply that the terminal hydroxyl groups of the PEG molecules interact with BSA molecules, changing the protein conformation in such a way that the interaction coefficient BSA-H2O (which came from the Flory-Huggins equation) changes accordingly. Bearing in mind that the most influential parameter in the protein activity is the interaction coefficient BSA-H2O, small changes lead to a significant change in the calculated value of this activity. It is thus possible to state that the average molecular mass value of PEG is the main factor that affects the equilibrium state.

Identiferoai:union.ndltd.org:IBICT/oai:teses.usp.br:tde-23012008-102844
Date12 November 2007
CreatorsCarlos Eduardo Kolb Maynardes Araujo de Campos Jordão
ContributorsPedro de Alcântara Pessôa Filho, Silas Derenzo, Beatriz Vahan Kilikian
PublisherUniversidade de São Paulo, Engenharia Química, USP, BR
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Sourcereponame:Biblioteca Digital de Teses e Dissertações da USP, instname:Universidade de São Paulo, instacron:USP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0028 seconds