Controladores Robustos LQG/LTR com AÃÃo Integral Aplicados ao Controle de Geradores EÃlicos Interligados ao Sistema de DistribuiÃÃo de Energia ElÃtrica Baseados em MÃquinas de InduÃÃo Duplamente Alimentada / Robust Controller LQG/LTR with Integral Action Applied to Control of Wind Generators connected to Distribution Power System based on Doubly Fed Induction Machine

FundaÃÃo Cearense de Apoio ao Desenvolvimento Cientifico e TecnolÃgico / Na presente tese, propÃe-se um controlador robusto LQG/LTR (Linear Quadratic Gaussian with Loop Transfer Recovery) com aÃÃo integral (LQG/LTRI) em uma nova aplicaÃÃo para o ajuste dos controladores do conversor do lado da mÃquina e do conversor do lado rede elÃtrica em um sistema de conversÃo eÃlica utilizando um gerador de induÃÃo duplamente alimentado (Doubly-Fed Induction Generator - DFIG).
A metodologia de controle proposta assegura a robustez em relaÃÃo à rejeiÃÃo do erro de rastreamento, insensibilidade a variaÃÃes paramÃtricas, alÃm de permitir que erros de medida e modelagem sejam incorporados no projeto. Testes de robustez e desempenho foram realizados para variaÃÃes dos parÃmetros internos da mÃquina e variaÃÃes de referÃncia de velocidade.
Resultados de simulaÃÃo e experimentais, obtidos em um protÃtipo de laboratÃrio com uma mÃquina de 2kW sÃo apresentados para validar e demonstrar o bom desempenho e robustez do controlador proposto comparado com os controladores clÃssicos Proporcional-Integral (PI) em um sistema de geraÃÃo eÃlica com mÃquinas DFIG. / It is proposed in this thesis a LQG/LTR robust controller (Linear Quadratic Gaussian with Loop Transfer Recovery) with integral action (LQG/LTRI) in a new application for gain tuning for the rotor side converter and grid side converter in a wind energy conversion system (WECS) with Doubly-Fed Induction Generator(DFIG).
The proposed control method assures the robustness with respect to the tracking error rejection, insensitivity to parameter variations and permits that measurement and modeling errors are incorporated in the project. Robustness and performance tests were performed for variations of machine internal parameters and speed.
Simulation and experimental results, obtained from a laboratory prototype that uses a 2 kW machine are presented to validate and demonstrate the robustness and performance of the proposed controller through the comparison with the proportional and integral (PI) controller employed in a wind energy conversion system with DFIG.

Identiferoai:union.ndltd.org:IBICT/oai:www.teses.ufc.br:5206
Date27 January 2012
CreatorsVandilberto Pereira Pinto
ContributorsJosà Carlos Teles Campos
PublisherUniversidade Federal do CearÃ, Programa de PÃs-GraduaÃÃo em Engenharia ElÃtrica, UFC, BR
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/doctoralThesis
Formatapplication/pdf
Sourcereponame:Biblioteca Digital de Teses e Dissertações da UFC, instname:Universidade Federal do Ceará, instacron:UFC
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0025 seconds