Return to search

Reduction of oil pump losses in automatic transmissions

In the vehicle industry it is of great interest to reduce the emissions and lower the fuel consumption.Up to now a lot of effort has been put into increasing the efficiency of the engine,but it starts to get expensive to keep improving the engine. In this master thesis the transmissionand especially the oil supply to the transmission is investigated. An example of how the requirements of an oil pump can be decided is described. Knowingthe requirements different pumps may be adapted to meet the demands. The gear pumpused today is compared with a variable displacement pump and an electric pump. The gearpump is not possible to control, but the other two are. A few simple control strategies areintroduced. The strategies are implemented and the three pumps are used in the same drivecycle. It is shown that it is possible to reduce the energy that the pump requires if it isreplaced by a variable vane pump or an electric pump.

Identiferoai:union.ndltd.org:UPSALLA1/oai:DiVA.org:liu-111937
Date January 2014
CreatorsLarsson, Camilla
PublisherLinköpings universitet, Fordonssystem, Linköpings universitet, Tekniska högskolan
Source SetsDiVA Archive at Upsalla University
LanguageEnglish
Detected LanguageEnglish
TypeStudent thesis, info:eu-repo/semantics/bachelorThesis, text
Formatapplication/pdf
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0025 seconds