Return to search

Design of reinforced concrete inverted-T beams for strength and serviceability

Significant diagonal cracking in reinforced concrete inverted-T straddle bent caps has been reported throughout the State of Texas. Many of the distressed structures were recently constructed and all have been in service for less than two decades. The unique nature of the problem prompted a more detailed look into the design and behavior of such structural components.
Strut-and-tie modeling is currently recommended for design of deep (rectangular) beams, but its application to more complex structures has not been fully explored. Due to concerns with current design provisions the application of strut-and-tie modeling to inverted-T beams was investigated along with serviceability-related considerations in this dissertation.
An experimental study was conducted in which thirty-three reinforced concrete inverted-T beam tests were conducted. The effects of the following variables were evaluated: ledge depth and length, quantity of web reinforcement, number of point loads, member depth, and shear span-to-depth ratio. A strut-and-tie design method proposed by Birrcher et. al (2009), initially calibrated for compression-chord loaded deep beams, was investigated. It was concluded that the strut-and-tie method was a simple and accurate design method, and it was recommended for use in inverted-T beam design. A
vi
recommendation was also made for the amount of minimum web reinforcement needed for strength and serviceability considerations. A simple service-load check was proposed for the purpose of limiting diagonal cracking under service loads. Finally, a chart was created to aid in the evaluation of distressed, diagonally-cracked inverted-T bent caps in the field. / text

Identiferoai:union.ndltd.org:UTEXAS/oai:repositories.lib.utexas.edu:2152/21270
Date23 September 2013
CreatorsLarson, Nancy Anne, 1986-
Source SetsUniversity of Texas
Languageen_US
Detected LanguageEnglish
Formatapplication/pdf

Page generated in 0.0017 seconds