Back to search

University of Adelaide

The development of a precision dual bending system for bio-micropipette production

Abstract

dc:description.abstract

Micro glass pipettes are widely used tools for hand ling oocytes, sperms and embryos for ln Vitro Fertilisat ion (IVF) procedures and also for cells or fluids in biological laboratory works. Since all these cells are microscopic in dimension, the pipette tip that handles the cells is required to be microns in diameter so that a precise and delicate manipulation can be achieved while minimising damage to the cells. As a unique tool for lVF, Z-shaped micro glass pipettes enable a low-angle entry and facile alignment of the pipette in the procedure and are utilized by rapidly increased numbers of scientists and operators. The nature of the procedure demands stringent quality requirements on the pipette geometry. However, like many other laboratory glassware, the bending of Z pipettes is still predominately a manual process. The product quality relies heavily on the skills and experience of operators, which leads to high rejection rate and low productivity. Glass is a viscoelastic material in the transformation range. lts deformation process that does not have distinguished elastic and plastic deformation phases is not well studied and documented due to the complexity of constitutive models. 111 addition to this complexity, micro glass pipette characterized as thin wall and tiny diameter lacks large quantity of research data for deformation process automation. This research focuses on the development of a precise and novel bending system for Z-shaped pipettes. The development is based on a sound understanding of heat transfer and temperature distribution profile in the glass pipette and pipette bending behaviour. As a result of this understanding, the research leads to a mechanical and electrical design of abending system. Two fundamental aspects on the knowledge about the bending of glass pipettes are investigated. The first is focused on the heat transfer and temperature distribution in the glass pipette. It is initiated from the understanding of thermal properties of borosilicate glass and identification of suitable temperature range for bending. Various heating sources are compared to determine the most suitable one for this application. Electrical filament is eventually selected because it is easier to be automatically and precisely controlled on heating temperature and time. Computational fluid dynamic (CFD) simulation is employed to investigate the heat transfer and temperature distribution in the glass pipette. The investigation makes it possible to determine the geometry and configuration of the filament for an efficient heating process. The study for the second aspect is concentrated on the bending profile of the glass pipette for a better understanding on the influential factors in the bending process which include the width and surface temperature of fi lament, and the heating and bending time. Both experimental and computational methods are applied in the study on the effects of the factors on the bending quality that is represented by the smoothness of the bending profile. The most influential factor is identified and a set of optimized parameters is determined to ensure quality bends of the pipette. Based on the above knowledge, the research moves to the implementation stage where abending system is developed to consistently achieve the above-identified bending temperature and desired operating parameters for production of good quality bends of pipettes. The system consists of three main subsystems including mechanical, thermal and electrical control. Eventually the subsystems are integrated, tested and evaluated. The evaluation is conducted by examining the bending quality and its consistency against the pipette product specifications. Very positive results are observed from the evaluation. Meanwhile, the evaluation also demonstrates the validity of the acquired knowledge about the temperature, heating profiles and bending behaviours of micro glass pipettes.

Degree

thesis:*
College dc:contributor.school
University of South Australia. School of Advanced Manufacturing and Mechanical Engineering
Year dc:date.issued
2009

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Xia, Wei

Subjects

dc:subject × 4

Rights

Language dc:language.iso
en

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/11541.2/39808

Chain of custody

source
Harvested from
University of Adelaide
Base URL
digital.library.adelaide.edu.au/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Xia, Wei. The development of a precision dual bending system for bio-micropipette production. 2009. https://hdl.handle.net/11541.2/39808