dc:description.abstractUmbilical venous and arterial catheters (UVCs and UACs) are essential for administering fluid, medication, and monitoring blood for premature or critically ill infants. However, many catheters fail due to adverse events (AEs) and knowledge of AEs is limited. Globally, 13% of UVCs and 9% of UACs are associated with an AE, and local incidence is much higher (71% for UVCs and 44% for UACs). Catheter malposition is the most common AE and can delay treatment. A risk prediction model for UACs identified the following predictors: thrombocytopenia, intrauterine growth restriction/small for gestational age, congenital heart defects, maternal diabetes, and a dwell time of greater than seven days. The research contained in this thesis calls for improved practices, including ultrasound-guided insertion and routine tip surveillance to reduce AEs and improve health outcomes.