University of Adelaide
A non-linear parametric oscillator with applications to residual current detection
Abstract
dc:description.abstractSafety is a major issue in the distribution and application of electrical energy. Despite advanced technology many people are still electrocuted each year by accidentally coming in contact with a.c. voltages above 50 volts, mostly from the mains distribution system. Together with the establishment of suitable earthing systems, the most important contributor to reducing the danger of electrocution is the residual current device (RCD). Nuisance tripping occurs when an RCD disconnects the mains, even though there has been no threat of an electric shock condition to a person. Nuisance tripping limits the usefulness of RCD's because it unnecessarily disrupts power systems and places practical limits on the RCD's sensitivity to life threatening current levels. Nuisance tripping is increasing. This is because its instigators, which include switch mode power supply loads, use of switched reactors in the power supply system and standing capacitive leakage in cable systems, are becoming more significant. Yet it was observed from the literature that a systematic quantitative assessment of RCD's for nuisance tripping, did not exist.
Degree
thesis:*- College dc:contributor.school
- University of South Australia. School of Electrical and Information Engineering.
- Year dc:date.issued
- 2002
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Delic, Dennis,
Subjects
dc:subject × 3Rights
- Language dc:language.iso
- en
Identifiers
dc:identifier.*- Handle dc:identifier.uri
- https://hdl.handle.net/1959.8/82385