dc:description.abstractA geo heat exchanger (GHE) utilises a pipe configuration, buried in the ground, to harvest geothermal energy at shallow depths. A GHE could be used in heating and cooling systems as the ground temperature is normally higher than the average air temperature in winter and lower in summer. This difference in the temperature can be utilised to improve the efficiency of air conditioning systems (in summer) and heat pumps (in winter). Two basic arrangements of GHEs are commonly used: vertical and horizontal. Vertical GHEs, which are particularly suitable for confined spaces, generally have a better performance due to stable soil temperature deep down in comparison with the horizontal arrangement. However, their installation cost is relatively high. Meanwhile, the efficiency of horizontal GHEs may benefit from ambient temperature fluctuations and lower installation costs due to the shallow depth of burying of GHEs. However, this arrangement requires a large land area for installation, which may substantially increase the capital cost. In addition, GHEs’ performances, especially for vertical ones, may suffer deterioration with an increase in the operation times due to heat or (coldness) accumulation in the soil. In this study, a combined horizontal-vertical GHE arrangement is proposed to synergy the benefits of the two configurations and negate their disadvantages. The overall aim of this project is to understand the thermo-dynamic performance of GHEs (including the horizontal, vertical and combined GHE) under various loads and weather/soil conditions, in order to optimise their designs and operations by developing validated computational models of the heat exchangers. Mathematical models for both horizontal and vertical GHEs have been developed which take into account the fluctuations in soil temperature during seasonal changes. The newly developed models are different from the existing models most of which overlooked the seasonal changes in soil temperature. In the new models, the seasonal changes in soil temperature, which are affected by the thermal interaction between the ground and the atmosphere, are incorporated with a help of an internal source term approach. The values of the internal source term depend on geographic locations and soil depths. The finite difference method is used to obtain the numerical solution of the proposed GHE models. The models are validated using experimental data obtained from custom-built rigs. The simulation results show that the new approach, which takes into account the effect of seasonal periodic soil temperature fluctuations on the performance of the GHE, agrees well with experimental data. The validated models are then used to conduct a sensitivity analysis with the aim of investigation of the effect of design parameters on the performance of the horizontal, vertical and combined GHE. Outcomes of two case studies are presented to demonstrate the benefits of the combined GHE. The first study was conducted to assist with the operation of cooling systems of Terminal 1 building of the Adelaide airport. The second study analysed the efficiency of the combined GHE for an air conditioning system (heat pump) for twenty units of residential houses. The thesis has been organised into eight chapters. The structure of the thesis is summarised as follows: Chapter 1-Introduction: This chapter introduces background, gaps identified in GHEs research area, aims and objectives of the study, contributions to the field, and scope and limitations. Chapter 2-Literature review: This chapter provides a brief description of ground source air conditioning systems (heat pumps), soil thermal characteristics, the review of GHE models and operation modes, and thermodynamic analysis to account the energy savings of the ground source air conditioning systems (heat pumps). The chapter concludes with a summary of the literature review. Chapter 3-Seasonal soil temperature changes: The chapter elaborates the method used in order to determine the profile of soil temperature at various depths for a specific day in a year. In addition, it summarises a new approach to model the soil temperature fluctuations during seasonal changes on the GHE’s performance. In which the seasonal soil temperature changes are expressed as an internal source term and incorporated into the GHE model. Chapter 4-Horizontal GHE: This chapter presents the developed mathematical model for the horizontal GHE and outcomes of the comparison with experimental data obtained with a reduced scale GHE custom-built rig. It is followed by sensitivity analysis to investigate the technical parameters affecting the performance of the GHE. Chapter 5-Vertical GHE: The mathematical model that predicts the performance of the vertical GHE is presented in this chapter. An experimental study utilising a scale down experimental rig has been conducted to validate the model. Then, the sensitivity analysis is performed using the validated model to investigate the effect of some design and operational parameters on the vertical GHE’s performance including borehole thermal conductivity, borehole depth, fluid flow rate, and types of carries fluids. In addition, the dynamic performance of the GHE under continuous and intermittent loads is also investigated. Chapter 6-Combined horizontal-vertical GHE: This chapter analyses the performance of a combined horizontal-vertical GHE based on the two separate validated models. Chapter 7-Case studies: This chapter demonstrates the potential applications of the combined GHEs to assist in the operation of air conditioning systems. These two studies are focused on the analysis of the combined GHE for the Terminal 1 building, Adelaide airport and twenty units of residential buildings. Chapter 8-Conclusion: This chapter summarises the result of this thesis and discusses the future work.
Degree
thesis:*- College dc:contributor.school
- School of Mechanical Engineering
- Year dc:date.issued
- 2018
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Sofyan, Sarwo Edhy
- Advisors dc:contributor.advisor
-
- Hu, Eric
- Kotousov, Andrei
Subjects
dc:subject × 3Rights
- Language dc:language.iso
- en
Identifiers
dc:identifier.*- Handle dc:identifier.uri
- https://hdl.handle.net/2440/132767