Back to search

University of Adelaide

Investigating the biomechanics and genetics of acetabular peri-prosthetic osteolysis

Abstract

dc:description.abstract

Osteolytic lesions in the acetabulum of the pelvis, as a long-term consequence of total hip arthroplasty (THA), can lead to implant loosening and failure. These lesions are primarily considered to be a result of peri-prosthetic cells responding to wear debris generated mechanically from the implant. However, it has also been hypothesised that stress shielding may contribute. Therefore, the central aim of this thesis was to combine computational and biological methods to investigate the contribution of stress shielding and particle disease in the development of acetabular osteolytic lesions. The first experimental study in this thesis developed an accurate and reliable approach for measuring lesion volume within anatomical regions of interest within CT scans. Accuracy and reliability tests were performed on CT scans of cadavers with simulated lesions and increasing numbers of total hip arthroplasties in situ as CT clarity disrupting metal artefact is more severe with two implants present. Organ scale micro-CT was used to obtain a reference value to which the accuracy lesion measurements were compared against. The method was found to be suitably accurate and reliable although accuracy and reliability of quantifying lesions volume decreased with more implants in situ. The second experimental study developed patient-specific finite element (FE) models of THA recipients with developed acetabular osteolytic lesions. In addition, this study simulated a patient’s pelvis and implant immediately after primary THA from CT scans taken prior to revision THA. Four different approaches for assigning material properties to trabecular bone were tested when mapping the entire geometry material properties from the CT scan was not possible due to metal artefact and/or missing bone. It was found that strain distribution remained consistent for all approaches and that having set generic material properties provided the most valid train values for the osteolytic models. It was concluded that assigning set generic material properties throughout the entire pelvis was a better solution than those that were more complex. Strains output from the simulated primary FE models were comparable to those reported in the literature and strains output from FE models for the contralateral side of a unilateral THA patient with a virtually implanted THA cup. They were, however, considerably different (~2,000 - 8,000 microstrain) to those found using the FE models with acetabular osteolytic lesions present. Therefore, the geometric assumptions used in the FEA models simulating the pelvis immediately after primary THA were reasonable. The final experimental study, which was a pilot study, combined the modelling approaches from the first two studies with gene expression from regional bone samples obtained during surgery to investigate biomechanics and biology of acetabular peri-prosthetic osteolysis on a patient by patient basis. The aim of this study was to investigate if there were associations between regional strains, regional volume of bone loss in the acetabulum and regional expression of genes related to bone loss. The regions of the acetabulum with the highest volume of bone loss were associated with the regions with the lowest strains and vice versa. However, this association was not observed for models simulating the pelvis/implant before lesion development. Furthermore, the regions with highest expression of DKK-1 were associated with the regions with the highest strain and lowest bone loss. This association was also found with RANKL. The results of this thesis provide, for the first time, evidence that stress shielding facilitates the development of osteolytic lesions. These results also suggest that this facilitation only occurs subsequent to initial lesion development. Long term modifications in both volume of bone loss and distribution of strains through the acetabulum were associated with regional gene expression. It appears likely that regions of low bone loss are sites of active osteoclastogenesis, possibly exacerbated by overloading.

Degree

thesis:*
College dc:contributor.school
Adelaide Medical School
Year dc:date.issued
2021

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Grace, Thomas Michael
Advisors dc:contributor.advisor
  • Thewlis, Dominic
  • Atkins, Gerald
  • Solomon, Lucian Bogdan
  • Taylor, Mark (Flinders University)

Subjects

dc:subject × 1

Rights

Language dc:language.iso
en

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/2440/138189

Chain of custody

source
Harvested from
University of Adelaide
Base URL
digital.library.adelaide.edu.au/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Grace, Thomas Michael. Investigating the biomechanics and genetics of acetabular peri-prosthetic osteolysis. 2021. https://hdl.handle.net/2440/138189