University of Adelaide
Lu-177 Automated Quantification Capabilities of Siemens Symbia Intevo 16.
Abstract
dc:description.abstractThe use of Lu-177 to treat metastatic prostate cancer and neuroendocrine tumours was introduced to Sir Charles Gairdner Hospital (SCGH) in 2018. Along with its introduction came an interest in dosimetry using absolute quantification. The installation of a new SPECT/CT (Siemens Symbia Intevo) with automated quantification abilities for Lu-177 required investigation into the scope of its capabilities and comparison to manual quantification. While there are studies on automated quantification of Tc-99m, there is little on Lu-177. The aim was to determine which of automated and manual quantification is more accurate when considering Lu-177 in a clinical context as well as the optimal measurement conditions in a clinical context. To cover a wide clinically applicable patient uptake range, a NEMA phantom study was designed. Prior to the phantom study, the accuracy of the dose calibrator and deadtime effects were addressed. Optimal measurement conditions for Lu-177 in a vial and syringe were determined; both are clinically relevant and applied to this study. The Lu-177 manufacturers’ activity was used for comparison since their equipment is officially calibrated more frequently. No correction factor was necessary and approximately 10 cm from the base of the well was the optimal position for both vial and syringe measurements. Deadtime effects are isotope, collimator and camera specific and can have a profound impact on quantification results. Traditional methods to determine deadtime effects were unsuitable due to the relatively long half-life of Lu-177. A new intrinsic method using multiple small sources of Lu-177 in the middle of the FOV facilitated collection of a large volume of data in a shorter period of time. A count rate threshold for deadtime was determined and applied to the extrinsically acquired phantom data. It was determined that no deadtime correction was necessary for this study. Blood concentration and tumour/organ uptake were used as phantom study design guidelines. A literature review of blood concentration and tumour/organ uptake from 24 hours post therapy onwards was considered in the design. This is the earliest clinically applicable scan for patients at SCGH. Blood concentration was represented by phantom background activity concentration and tumour/organs by fillable spheres. Phantom acquisition occurred once per day for 20 days with the background concentration manually altered to create a range of background to sphere ratios. A clinically based scan protocol with MELP collimators, 208 keV photopeak and Triple Energy Window scatter correction was applied. Dual reconstruction, labelled XSPECT and 3D Flash for automated and manual quantification respectively, were used. Automated and manual quantification results were collected in Siemens software Syngo.Via using auto-contouring tool labelled Response Evaluation Criteria in Solid Tumors (RECIST). Data was collected using RECIST 10, 20, 30 and 40% thresholds of the maximum counts, with and without recovery coefficients for partial volume correction. Automated XSPECT quantification improved accuracy compared to manual 3D Flash quantification. A 30% RECIST threshold without partial volume correction were the optimal measurement conditions, differing from the current clinical standard of 40% when considering Lu-177.
Degree
thesis:*- College dc:contributor.school
- School of Physics, Chemistry and Earth Sciences
- Year dc:date.issued
- 2022
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Grigoroff, Lucy Joy
- Advisors dc:contributor.advisor
-
- Pollard, Judith
- Storm, Cameron
Subjects
dc:subject × 3Rights
- Language dc:language.iso
- en
Identifiers
dc:identifier.*- Handle dc:identifier.uri
- https://hdl.handle.net/2440/138247