Back to search

University of Adelaide

Characterisation of the relationship between Radiofrequency Catheter Ablation Parameters and Atrial Fibrillation Ablation Lesion Formation

Abstract

dc:description.abstract

Atrial fibrillation is the most common sustained arrhythmia in humans, affecting up to 5% of individuals over 50-years of age. AF results in a gamut of clinical sequelae with devastating consequences, including fivefold increased risk of stroke, greater vulnerability to dementia, and near double rates of mortality than the general population. Despite the improved understanding of AF development, the arrhythmia remains a major public health concern and a huge economic burden due to suboptimal management. Therefore, in this thesis, we employed both meta-analysis and ex vivo porcine models to investigate the effects of radiofrequency catheter ablation parameters on ablation lesion formation. In chapter II, we conducted systematic review with meta-analysis comparing catheter ablation for atrial fibrillation guided by indices incorporating force, power, and time versus contact force-guided only for 1) acute procedural endpoints, and 2) outcomes at 12 months. The findings demonstrated that radiofrequency ablation guided by ablation index was associated with a higher level of success in first pass isolation, lower rates of acute pulmonary vein isolation reconnection, and greater freedom from AF, highlighting that indices predicting transmural lesion may improve ablation outcome. Given our findings of the predictive power ablation indices in ablation outcomes, we aimed to further characterise these relationships using established ex vivo porcine heart model. Chapter III describes the porcine ex-vivo setup utilised for the assessment of the determinants of lesion growth with radiofrequency energy-based catheter ablation. Also described in this chapter were the methodologies used for lesion assessments and lesion parameters assessed. In chapter IV, we examined and assessed lesion size formation from catheter ablation in porcine ventricular muscle slabs with the objective of testing the hypothesis that the protocol of lesion creation and assessment are reproducible, repeatable, and reliable. Our results demonstrated inter- and intraobserver reliability measures of 99.1% and 98.8%, indicating that the method employed in this study was accurate and reliable for the assessment and characterisation of lesion formation after catheter ablation in porcine myocardial tissues. In chapter V, we evaluated lesion growth, time to maximum lesion size steam pops, and safety with time across a range of power settings using a contemporary technology ablation catheter with surrounding flow irrigation. We showed that similar maximal lesion volumes are seen across a range of power settings; at the same time, the time to reach peak lesion dimensions and volume decreases with increasing power, but at the expense of lowering of safety margins and increasing risk of steam pops. In chapter VI, we evaluated the effect of contact force on lesion metrics and the interaction with power metrics. The results showed that ablation lesion is insubstantial at the settings of both low contact force and power. Higher force settings were not associated with a significant increase in lesion endocardial diameter and depth but resulted in significantly greater lesion width and volume. For all lesion parameters, the relationship between force and lesion becomes significant at high power settings. Chapter VII reports the evaluation of the effect of contact force, power, and time on area of endocardial sparing. All three variables of time, power, and force are significant predictors of endocardial sparing metrics, although correlation is moderate for width and area, and weak for depth. Although width of the endocardial sparing was significantly less with 50W, there was no difference in area of endocardial sparing across various power settings ranging from 20 to 50W. The strength of our work is the large number of experiments with across a wide range of clinically used parameters (force and power) which have not been reported together except under in silico conditions. Taken together, these findings have provided improved understanding of the clinical, biophysical, and fundamental relationships between ablation parameters (time, force, and power) and lesion formation, which could have far-reaching implications for the management of atrial fibrillation.

Degree

thesis:*
College dc:contributor.school
Adelaide Medical School
Year dc:date.issued
2023

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Rattanakosit, Tira
Advisors dc:contributor.advisor
  • Boyd, Mark
  • Page, Amanda
  • Mahajan, Rajiv

Subjects

dc:subject × 1

Rights

Language dc:language.iso
en

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/2440/138929

Chain of custody

source
Harvested from
University of Adelaide
Base URL
digital.library.adelaide.edu.au/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Rattanakosit, Tira. Characterisation of the relationship between Radiofrequency Catheter Ablation Parameters and Atrial Fibrillation Ablation Lesion Formation. 2023. https://hdl.handle.net/2440/138929