Back to search

University of Adelaide

Advances in Linear Endobronchial Ultrasound Transbronchial Needle Aspiration

Abstract

dc:description.abstract

Introduction: Linear endobronchial ultrasound (EBUS) transbronchial needle aspiration (TBNA) is the definitive procedure to investigate mediastinal lymphadenopathy in benign and malignant conditions. As most lung cancers have lymph node involvement at diagnosis, linear EBUS TBNA can often diagnose and stage in one procedure. Failure to obtain adequate tissue for ancillary tests results in repeat procedures so improvements in sample quality and size are worthwhile. This thesis aims to evaluate new ideas in linear EBUS. - Rapid onsite evaluation (ROSE) of EBUS-TBNA increases diagnostic accuracy but in many institutions requires a specialist pathologist. Medical scientists or respiratory registrars are options if they can demonstrate equivalence to a specialist pathologist. - Both 22G Olympus needle and Echotip 22G ProCore needles have a bevelled tip, but the ProCore needle also has a reverse lateral bevel. This needle feature collects tissue during retrograde withdrawal but it is not yet known if this improves diagnostic rate or sample suitability for ancillary tests. Methods: (i) Accuracy of ROSE of linear EBUS TBNA by respiratory registrars in training and medical scientists compared to specialist pathologists—an initial pilot study ROSE was performed on the first two EBUS-TBNA passes per patient by a pathologist, a medical scientist and two senior respiratory registrars. Each ROSE reviewer recorded whether each sample was sufficient or insufficient. Pathologist interpretation was gold standard. (ii) Randomised Control Trial of Linear EBUS – TBNA using 22G ProCore needle versus 22G Olympus needle Patients undergoing linear EBUS were randomised to 22G Olympus needle or 22G ProCore needle. The result of each TBNA pass was documented as sufficient or insufficient at rapid onsite examination (ROSE). Diagnosis and suitability for ancillary tests were recorded. Results: (i) ROSE by specialist pathologists deemed 16/50 (32%) sufficient and 34/50 (68%) insufficient respectively. Medical scientists were 90% concordant with pathologist (p=0.056). The two respiratory registrars were 78% (p<0.05) and 74% (p<0.05) concordant, respectively. A diagnosis was established in 21/25 (82%) patients, either malignant (14/25 [56%]) or benign (11/25 [44%]). (ii) Eighty patients were recruited to Procore or Olympus needle. Cases were benign (34), malignant (34) or insufficient (12).Despite the first two passes having a high degree of insufficient samples, the overall diagnostic rate was higher for Olympus (45/49 [92%]) than Procore (23/31 [75%]) but this did not reach statistical significance (Fisher exact statistic =0.0514 [p=<0.5]). For procedures with confirmed adequacy at ROSE, mean number of passes required before adequacy was 1.9 for Olympus and 2.7 for Procore. Cell block diagnostic yield was similar (Olympus 57%, Procore 51%). For malignant cases, there was no significant difference in sufficiency for immunohistochemistry (Olympus 80%, Procore 79%). Conclusion: Objective evaluation of new ideas guides clinical practice in linear EBUS TBNA. Medical scientist review of ROSE is not significantly different to a specialist pathologist and is an acceptable alternative. Respiratory registrars are not an acceptable alternative without more intensive training. While the difference between the 22G Procore needle and 22G Olympus needle was not statistically significant, there was a trend favouring diagnostic accuracy for the 22G Olympus needle.

Degree

thesis:*
College dc:contributor.school
Adelaide Medical School
Year dc:date.issued
2024

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Hopkins, Emily
Advisors dc:contributor.advisor
  • Jersmann, Hubertus
  • Nguyen, Phan

Subjects

dc:subject × 6

Rights

Language dc:language.iso
en

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/2440/144190

Chain of custody

source
Harvested from
University of Adelaide
Base URL
digital.library.adelaide.edu.au/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Hopkins, Emily. Advances in Linear Endobronchial Ultrasound Transbronchial Needle Aspiration. 2024. https://hdl.handle.net/2440/144190