University of Adelaide
Concrete Columns Lightly-confined with Sustainable Hybrid Fibre-Reinforced Polymer Jackets
Abstract
dc:description.abstractFibre-reinforced polymer (FRP) composites are popular confining materials to enhance the strength and deformability of existing concrete columns. Most research to date has focussed on jacketing for strength enhancement where the ratio of enhanced axial strength to original column strength is above 1.5. When deformability enhancement is of primary concern with the need for large strength enhancement, then jacketing providing light confinement with a ratio less than 1.5 is needed. There is, however, less research by comparison across the board on lightly-confined systems, in addition to other contributing factors such as bonded versus unbonded jackets as well as jackets made from large rupture strain FRP (LRS-FRP), as well as sustainable and recycled fibres. This program of study employed a three-stage experimental program to investigate FRP lightly-confined concrete using sustainable basalt FRP (BFRP) and recyclable polypropylene FRP (PPFRP), with benchmarking to traditional carbon FRP (CFRP). In addition, bonded and unbonded jackets were considered and fibres were also utilised in combination with each other to produce hybrid jacketing solutions. To investigate the effects of FRP and bond type on confined concrete in low confinement conditions, stage one of the study employed a total of 36 concrete specimens lightly-confined by bonded or unbonded CFRP, BFRP and PPFRP jackets. Tests show that the unbonded FRP jacket does not noticeably affect the confined concrete strength but does improve the ultimate compressive strain with the FRP strain utilisation ratio improved by approximate 35% for CFRP and BFRP. This trend is ceased when the LRS-FRP (PPFRP) is used. Moreover, the results indicate that predictive models need to consider the distinct stiffness and strain characteristics of individual FRPs for lightly-confined concrete. The second experimental program investigated 26 hybrid FRP lightly-confined concrete specimens using bonded and unbonded CFRP, BFRP, and PPFRP either separately or in combination with each other to produce hybrid jacketing solutions. The study observed clear progressive damage for most of the hybrid FRP jackets. A simple spring analogy was presented to mimic the progressive damage of a hybrid jacket. It was also evidenced that adding a small amount of stiffer CFRP effectively improves the stiffness of confined concrete and overcomes the limitations imposed by low stiffness BFRP and PPFRP fibres. An environmental and economical assessment of hybrid FRP systems is also provided to show that hybrid FRP systems are viable solutions from a range of different perspectives. The final experimental program investigated the influence of larger sized specimens where the main test variables were height and diameter (and height-diameter ratio) on 50 column specimens. The test results obtained as well as investigations on tests found in the literature show clear trends between FRP jacket capacity and column height and diameter. A new stress-strain model for PPFRP-confined concrete was proposed based on the experimental findings and it was calibrated with an assembled database from the open literature as well as tests undertaken in this study. A worked design example is finally provided that utilises the PPFRP-confined concrete model proposed using the stage three test results, where the example should prove of value to design engineers. Finally, overall conclusions are drawn and future research needs are identified.
Degree
thesis:*- College dc:contributor.school
- School of Architecture and Civil Engineering : Civil Engineering
- Year dc:date.issued
- 2025
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Wang, Xin
- Advisors dc:contributor.advisor
-
- Smith, Scott T.
- Visintin, Phillip
Subjects
dc:subject × 1Rights
- Language dc:language.iso
- en
Identifiers
dc:identifier.*- Handle dc:identifier.uri
- https://hdl.handle.net/2440/145193