Back to search

University of Adelaide

Development of a Birefringence Measurement System with a Hartmann Wavefront Sensor

Abstract

dc:description.abstract

This thesis describes the development of a novel system for fast measurements of twodimensional, path-integrated birefringence maps with a differential Hartmann Wavefront Sensor. The technique measures the wavefront change between polarisation states of a probe beam due to birefringence. Fast, precise measurements of birefringence will be crucial for upgrade pathways of future gravitational wave detectors. The performance of current gravitational wave detectors with fused silica test masses is partly limited by temperature gradients in the test masses. Crystalline test masses at cryogenic temperatures are promising candidates to reduce thermal gradients and thermal noise. However, intrinsic birefringence due to the crystal structure and additional birefringence from stresses can degrade detector performance. This has been observed in KAGRA, whose cryogenic sapphire test masses possess greater than expected birefringence. This has introduced a contrast defect to the interferometer, affected the behaviour of control signals and degraded detector sensitivity with intensity noise. Mapping and sensing birefringence in crystalline test masses will therefore be important in optimising the sensitivity of current and future gravitational wave detectors. The measurement system, which directly measures the retardance of a sample, was designed to be capable of in-detector measurements, and thus involved no moving parts. Polarisation states of the probe beam are therefore controlled with Pockels cells, which switch polarisation state with a negligible effect on the wavefront. In this thesis it is shown that the technique is only sensitive to spatially varying birefringence in a sample, not uniform birefringence. A custom Pockels cell is designed, which achieved an extinction ratio of 25dB operating as a half-wave plate and introduced an rms error of 0.5nm to the wavefront change, giving a noise floor of approximately 2mrad at 1550nm. This corresponds to a birefringence sensitivity as low as 5×10−10m−1. While attempting to validate the system, an interesting systematic effect was observed for which there is no explanation in literature to the best of our knowledge: changing the polarisation caused a shift in the diffraction pattern of the beam after the Hartmann plate. That is, the diffraction of the beam was polarisation dependent through an aperture 2 orders of magnitude greater in size than the beam’s wavelength. The magnitude and direction of this shift was dependent on the angle of incidence of the beam onto the Hartmann plate. A phenomenological model for the effect was constructed which agrees with experimental data.

Degree

thesis:*
College dc:contributor.school
School of Physics, Chemistry and Earth Sciences : Physics
Year dc:date.issued
2025

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Richardson, Mitchell
Advisors dc:contributor.advisor
  • Brown, Daniel
  • Veitch, Peter

Subjects

dc:subject × 6

Rights

Language dc:language.iso
en

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/2440/145688

Chain of custody

source
Harvested from
University of Adelaide
Base URL
digital.library.adelaide.edu.au/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Richardson, Mitchell. Development of a Birefringence Measurement System with a Hartmann Wavefront Sensor. 2025. https://hdl.handle.net/2440/145688