Back to search

University of Adelaide

Reference Night Aerosol Systematics at the Pierre Auger Observatory

Abstract

dc:description.abstract

The distribution of aerosols in the atmosphere above cosmic ray fluorescence telescopes must be well characterised to precisely recover extensive air shower properties such as the calorimetric energy, E, and the depth of shower maximum, Xmax. The Pierre Auger Observatory uses two centrally located laser facilities to measure the vertical aerosol optical depth (VAOD) every hour, as aerosol distributions can change rapidly with wind conditions. Historically, it has been assumed that the night with the clearest atmosphere each year is effectively aerosol free and that it is an appropriate reference to set the absolute scale of VAOD throughout that year. In this work, we perform a measurement of the systematic bias in the measured VAOD, chiefly attributable to reference night aerosols. In contrast to previous studies, we take a careful accounting of uncertainties to make more confident claims about the bias in VAOD. We investigate a variety of methods for assessing the measured VAOD, first by comparing simulated aerosol monitoring laser shots to real laser shots, then by comparing real air shower data from two independent detectors to probe the quality of the atmospheric model. Our key result is made using air shower events observed in stereo mode by the fluorescence detector. As this technique is only sensitive to the VAOD bias at a fixed altitude, to probe the height-dependence we combine it with a study of aerosol profiles independently measured using a lesssensitive Raman lidar system. This allows us to derive a complete model of the upper limit on the possible bias in the average measured VAOD, which we attribute primarily to an uncertainty on whether the annual reference nights are completely aerosol free. We formulate a correction for this bias and update the systematic and statistical uncertainties assigned to VAOD measurements to incorporate this new source of uncertainty. We retroactively apply the correction and uncertainty update to all VAOD measurements, then analyse a representative air shower dataset and discuss the small but significant effect of this new correction on the central values and uncertainties of E and Xmax.

Degree

thesis:*
College dc:contributor.school
School of Physics, Chemistry and Earth Sciences
Year dc:date.issued
2026

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Harvey, Violet Maitland
Advisors dc:contributor.advisor
  • Dawson, Bruce Robert
  • Bellido Caceres, Jose Alfredo

Subjects

dc:subject × 5

Rights

dc:rights
Statement dc:rights
  • © 2026 Violet M. Harvey. “Reference Night Aerosol Systematics at the Pierre Auger Observatory” is licensed under the Creative Commons Attribution-ShareAlike 4.0 International License. To view a copy of this license, visit https://creativecommons.org/licenses/by-sa/4.0/deed.en.
Language dc:language.iso
en

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/2440/152928

Chain of custody

source
Harvested from
University of Adelaide
Base URL
digital.library.adelaide.edu.au/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Harvey, Violet Maitland. Reference Night Aerosol Systematics at the Pierre Auger Observatory. 2026. https://hdl.handle.net/2440/152928