University of Adelaide
Microwave assisted laser-induced breakdown spectroscopy properties and applications
Abstract
dc:description.abstractLaser-induced breakdown spectroscopy (LIBS) is a spectrochemical analysis method based on laser-induced plasma as an emission source. There are a variety of applications for LIBS, such as food safety, forensics, geology, agriculture, medicine, and outer space discovery. The variety of applications is due to several advantages: real-time measurement, minimal or free sample preparation, stand-off, and multi-elemental analysis, to name a few. However, LIBS suffers from low sensitivity, low spectral resolution and high detection limits at atmospheric pressure in open air. This research presents microwave-assisted laser-induced breakdown spectroscopy (MW-LIBS) as a solution for LIBS limitations. Microwave-assisted laser-induced breakdown spectroscopy was demonstrated to Si quantitatively analyse atmospheric pressure in open air. The quantitative analysis for the element was performed in the liquid state. The measurement was performed under optimum laser energy, microwave power and gate delay parameters. The laser energy did not exceed 10 mJ, which is beneficial for splash reduction. The low laser energy usage and splash reduction were considered merits of MW-LIBS. The MW-LIBS recorded 51 signal enhancements for Si. The LoD of Si was 1.25 ppm using microwaves, 16-fold higher than LIBS. MW-LIBS was demonstrated for analysing hydrogen, boron, and chlorine isotopes in air and under atmospheric pressure. MW-LIBS resolved the distance between the isotope peaks of each element in molecular emission form (10BO, 11BO, 10BO2, 11BO2, Ca35Cl, Ca37Cl, OH, and OD). However, LIBS could not detect the emission of those that were detected by MW-LIBS. MW-LIBS was customised for deuterium quantitative analysis demonstration under atmospheric pressure in open air. The detected emission forms for the analysis were Dα and OD emission lines. The optimum gate delay for MW-LIBS emissions was investigated. The MW-LIBS emission SNR and FWHM improved when the gate delay increment increased. The optimum gate delay for MW-LIBS was at the earliest time when the MW-LIBS emission was free of LIBS emission. The optimum MW-LIBS gate width started at the optimum gate delay and continued to the end of the microwave pulse. The optimum gate delay and width were 10μs and 600 μs, respectively, when the FWHM of MW-LIBS emission was 0.054 nm, and the signal was 500-fold larger than the background noise. A comparison between detections using 2400 and 3600 line/mm diffraction grating using MW-LIBS OD emission was conducted. The SNR using 2400-line/mm was one-tenth the SNR using 3600-line/mm. The deuterium limit of detection (LoD) and limit of quantification (LoQ) were calculated using D and OD emission. Using 2400 line/mm diffraction grating and Dα emission, the MW-LIBS LoD and LoQ were 0.4% and 1.3%, respectively. Using 2400 line/mm OD radicals’ emission, the MW-LIBS LoD and LoQ were 0.85% and 2.8%, respectively. However, the MW-LIBS LoD and LoQ using 3600 line/mm diffraction grating were one-third of that 2400 line/mm diffraction grating. The traditional LIBS could not resolve the separation distance between hydrogen isotopes in atomic and molecular forms; therefore, it is an impractical technique for D quantitative analysis using a water matrix under atmospheric pressure in the open air. Then, MW-LIBS was assessed for qualitative and quantitative analysis of a limited quantity of samples under atmospheric pressure in open air. The samples, ore (21mg), Al2O3 (23mg), and Gypsum (55mg), were introduced to the laser beam using an acoustic levitation system. The levitated sample was exposed to unequal acoustic wave forces, which caused the sample to spin with an angular frequency of 7 Hz. This feature benefits laser-based analysis as a fresh sample is introduced at each laser pulse, eliminating the need for the usual mechanical devices. The Al emission lines at 394.3 nm and 396.11 nm were enhanced 119- and 193-fold using MW-LIBS in the AL2O3 sample. On the other hand, MW-LIBS recovered the Ca emission line profile from the severe self-reversal effect in a gypsum sample. Moreover, MW-LIBS detected multiple elements emission lines in the ore sample while LIBS missed several emission lines such as Fe emission lines; also, the MW-LIBS enhanced the emission lines of elements that were detected by both techniques; the minimum MW-LIBS enhancement was 46 for Al I (396.13 nm). Based on the single-shot analysis, it was found that ~80% of the laser pulses produced successful MW-LIBS-Levitation detection, confirming an impressive repeatability of the process. The microwave signal enhancement varies from one element to another. Therefore, the MWLIBS signal enhancement parameters were investigated at atmospheric pressure in the open air. The signal enhancement is strongly related to plasma temperature. Plasma temperature was studied as a function of gate delay. The plasma temperature was constant at 6000 K when the gate delay changed. Moreover, the atomic number and upper energy level were added as fundamental parameters to the investigation. The SNR of seven elements, Fe, Ag, Cu, Mg, Pb, S and Zn, was recorded using LIBS and MW-LIBS. The MW-LIBS improved the sevenelement SNR differently. The MW-LIBS’s SNR depended on the upper energy level value. The MW-LIBS signal-to-noise ratio showed a negative relation with the upper energy level. The microwave radiation was ineffective in enhancing the LIBS signal at an upper energy level equal to or greater than 8 eV. Finally, a simple model was developed to predict the MW-LIBS’s SNR improvements for elements. The model predicts that the highest SNR improvements were for the first group of the periodic table, where the upper energy levels were below 2 eV. However, microwave radiation did not improve the emissions of halides and noble gases.
Degree
thesis:*- College dc:contributor.school
- School of Chemical Engineering
- Year dc:date.issued
- 2025
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Alamri, Ali Mohammed
- Advisor dc:contributor.advisor
-
- Alwahabi, Zeyad
Subjects
dc:subject × 7Rights
- Language dc:language.iso
- en
Identifiers
dc:identifier.*- Handle dc:identifier.uri
- https://hdl.handle.net/2440/153179