University of Adelaide
Phase advance modulation of low-cost power electronic converters for SPM wind turbine generators.
Abstract
dc:description.abstractThis research investigates the control of low-cost power electronic converters for small-scale wind turbines under standalone applications. The system utilizes a surface permanent magnet (SPM) generator operating with a semi-bridge switched-mode rectifier (SMR) into a DC voltage load. Conventional control of a semi-bridge SMR results in lower output power than an inverter (i.e. fully-controlled voltage source rectifier) due to the SMR’s inability to control its input power factor. Phase-advance modulation was introduced by Rivas et al. as a method of generating increased output power from a semi-bridge SMR by modulating the leg voltage of each phase at three different levels during the phase current positive half cycle. This method produced a controllable leading phase shift on the phase current waveform with respect to the phase voltage. Previous studies focussed on using phase advance modulation to extract maximum power from Lundell alternator and interior permanent magnet (IPM) generators at a fixed speed (1,800 rpm). No research had been conducted on the performance of SPM generators under phase advance modulation techniques. This study examines how the voltage and power factor angle of a SPM generator can be controlled to ensure that the generator produces maximum output power at a given speed. A simplified version of phase advance modulation, called zero-epsilon modulation, is used to implement voltage-power factor angle control and hence extract the maximum value of power at a given SPM generator speed. Wind turbine generators are required to have controllable values of torque in order to perform maximum power point tracking. It is desirable therefore to be able to control a SPM generator used in wind turbines to a commanded value of torque while maintaining a high value of efficiency. This study will present the techniques required to use zero-epsilon modulation to control a SPM generator under maximum torque per ampere conditions, thereby minimizing generator copper losses. The voltage and power factor required by an inverter operating under maximum torque per ampere control for a given generator speed and commanded torque is used to calculate the required zero-epsilon control parameters. A closed-loop current controller was used to minimize the error between the commanded and actual values of generator torque. Simulation and experimental results are used to validate the proposed approach. The above research has demonstrated the feasibility of phase advance modulation as a low-cost alternative to inverter modulation for controlling a SPM generator to produce maximum output power at a given speed. In addition, phase advance modulation has been shown to be capable of controlling a SPM generator to produce a commanded value of torque under maximum torque per ampere conditions at a given speed. These results make a significant contribution towards the development of low-cost, high performance small-scale wind turbine generators.
Degree
thesis:*- College dc:contributor.school
- School of Electrical and Electronic Engineering
- Year dc:date.issued
- 2012
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Pathmanathan, Mehanathan
- Advisors dc:contributor.advisor
-
- Soong, Wen Liang
- Ertugrul, Nesimi
Subjects
dc:subject × 1Identifiers
dc:identifier.*- Handle dc:identifier.uri
- https://hdl.handle.net/2440/80724