University of Adelaide
The regulation of non-invasive medical devices in Australia: a case study of breast cancer imaging devices marketed direct-to-consumer.
Abstract
dc:description.abstractBackground: The premarket assessment of medical devices by an independent regulator is necessary to ensure that devices are safe and effective before they are made available to consumers in Australia. This responsibility is further necessitated by the practice of direct-to-consumer advertising (DtCA), whereby devices can be promoted to, and accessed by consumers without the involvement of a registered healthcare practitioner. An increase in the number of complaints against medical device advertising in Australia has raised questions around the effectiveness of the current regulations at ensuring that devices and their advertising material are adequately supported by evidence. Aims: The aim of this thesis is to explore the relationship between scientific evidence and DtCA in the policy context of medical device regulation in Australia. This aim is investigated using a case study of three emerging breast cancer imaging devices: digital infrared thermal imaging (DITI), electronic impedance scanning (EIS) and electronic palpation imaging (EPI). In this thesis, the evidence supporting the safety and effectiveness of these devices is evaluated, the nature and frequency of claims presented in online advertisements for these devices are assessed and compared against the available evidence, and stakeholders are engaged in a discussion around options to reform the regulation of medical devices and medical device advertising. Methods: A mixed methods approach was undertaken, involving three interrelated studies. The first study presents a systematic review of the available evidence for the safety and effectiveness of DITI, EIS and EPI. Following the systematic review, a quantitative content analysis was used to investigate the evidentiary basis of advertising claims made on websites that promote DITI, EIS and EPI in Australia. Finally, the results of the first two studies were used to inform stakeholder engagement around options to reform the regulation of medical devices and medical device advertising. Thematic analysis was used to synthesise stakeholder preferences in relation to a series of reform options proposed by Australia’s principal therapeutic goods regulator, the Therapeutic Goods Administration (TGA). Results: Study 1 As no direct effectiveness data were identified, the surrogate outcome measure of diagnostic accuracy became the primary focus of the systematic review. Significant heterogeneity was present among all three device classes, limiting the potential for meta-analyses. There was insufficient evidence to support the use of DITI, EIS or EPI for breast cancer screening, and the reported estimates of the sensitivity and specificity in symptomatic populations varied greatly for DITI (Sens 0.25-0.97, Spec 0.12-0.85) and EIS (Sens 0.26- 0.98, Spec 0.08-0.81), while only two poor quality studies were identified for EPI. Study 2 Thirty-nine Australian websites promoting DITI, EIS or EPI were identified. Despite a lack of primary evidence identified in the prior systematic review, the devices were advertised for diagnosis (n = 22 websites), screening (n = 20), prevention (n = 13) and risk factor identification for breast cancer (n = 13). Similarly, advertising claims of diagnostic accuracy (Sens 0.78-0.99, Spec 0.44-0.91) did not reflect the evidence base. Direct comparisons with conventional imaging were highly prominent (n = 31), and one third of websites explicitly promoted their device as a suitable alternative to conventional imaging (n = 12). Study 3 Sixteen stakeholders representing breast cancer research, patient advocacy and screening provided input into reforms to premarket medical device regulation and advertising proposed by the TGA. Participants highlighted important benefits and limitations of the proposed options. Differences between the TGA’s options for reform and stakeholder views indicated a need to update the current model for regulation that allows consumer choice and supports innovation, but within a more tightly regulated, safety-oriented framework. Conclusion: Online advertising claims made for DITI, EIS and EPI extend the indications and efficacy of these devices beyond the available research evidence. This disconnect suggests the regulatory framework tasked with ensuring the safety and efficacy of these devices and their promotion is in need of reform. Extending the current regulations for advertising preapproval to include medical devices, assessing diagnostic imaging devices for efficacy prior to market, and monitoring the use of a device in practice compared to its approved use on the Australian Register of Therapeutic Goods (ARTG) will help close the gap between DtCA and the evidence for emerging breast imaging devices.
Degree
thesis:*- College dc:contributor.school
- School of Population Health
- Year dc:date.issued
- 2014
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Vreugdenburg, Thomas Dion
- Advisors dc:contributor.advisor
-
- Hiller, Janet Esther
- Willis, Cameron
- Laurence, Caroline Olivia Mary
- Mundy, Linda
Subjects
dc:subject × 1Identifiers
dc:identifier.*- Handle dc:identifier.uri
- https://hdl.handle.net/2440/91251