Back to search

University of Alberta

A Tracheobronchial Specific in vitro Dissolution Test – A Problem Well Filtered is a Problem Half Dissolved

Abstract

dc:description.abstract

Inhaled pharmaceutical aerosols have been widely successful in treating a variety of lung diseases by delivering drugs directly to the site of action. For any therapeutic action to occur, solid drug particles must deposit on the airway surface, dissolve into lung fluid, and be absorbed by the local tissue. Accordingly, the efficacy of inhaled drugs can be improved by ensuring the drug is delivered to the targeted region in which its designed to treat when a local effect is desired. To better understand the dissolution step, the pharmaceutical industry relies on dissolution tests to evaluate the release of drug products delivered in solid dosage forms. For orally inhaled drug products, the development of dissolution tests is still an active field of research, owing in part to the challenge of collecting aerosol delivered from inhalers in quantities representative of those delivered to the targeted lung regions, in a manner suitable for presentation to a dissolution test apparatus. Although many dissolution test methods for inhaled drugs have been developed and described in literature, none currently accounts for regional lung deposition - despite its significant impact on therapeutic outcome. The aim of this thesis was to develop an in vitro dissolution test for inhaled drugs depositing in the tracheobronchial lung region. A recently developed in vitro apparatus for measuring regional lung deposition, which uses stainless-steel filters to capture the tracheobronchial dose, was used as the drug collection method. The design criteria for the dissolution test apparatus were: (i) to be insensitive to loaded dose (i.e., produce consistent results regardless of captured drug mass), and (ii) to be able to produce discriminatory dissolution results between inhalers with known dissolution differences. Prior to any dissolution experiments, filters were loaded with increasing drug mass using the deposition apparatus to first assess filtration sensitivity to loaded dose, revealing a linear relationship between delivered dose and captured drug mass. The custom dissolution test apparatus consisted of the tracheobronchial filters with captured drug being dissolved in a phosphate buffered saline containing 0.5% w/v sodium dodecyl sulphate solution at 37 °C. Samples were withdrawn at specific time points and quantified using highperformance liquid chromatography. The dissolution characteristics of the tracheobronchial dose of a commercial pressurized metered-dose inhaler and dry powder inhaler were compared. Dissolution measurements revealed: (i) no significant differences in dissolution results with increased drug mass, indicating that the method was insensitive to loaded dose, and (ii) slower dissolution rates for the pMDI as compared to the DPI, consistent with published findings. Collectively, these findings demonstrate the developed method’s robustness, repeatability, and ability to differentiate dissolution characteristics between formulations. The work done in this thesis could be applied in the testing of orally inhaled drug products, for quality assurance/control, evaluation of generics, drug development, and contribute to improved understanding of the dissolution of inhaled pharmaceutical aerosols in the lung fluids.

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
Master's
Grantor
University of Alberta
Year dc:date.issued
2025

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Huang, Alexander
Advisors dc:contributor.advisor
  • Martin, Andrew (Mechanical Engineering)
  • Warren, Finlay (Mechanical Engineering)

Subjects

dc:subject × 7

Rights

dc:rights
Statement dc:rights
  • This thesis is made available by the University of Alberta Library with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law.
Language dc:language.iso
en

Identifiers

dc:identifier.*
DOI dc:identifier.doi
https://doi.org/10.7939/81792

Chain of custody

source
Harvested from
University of Alberta
Base URL
era.library.ualberta.ca/oai
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
citation

Huang, Alexander. A Tracheobronchial Specific in vitro Dissolution Test – A Problem Well Filtered is a Problem Half Dissolved. Master's thesis, University of Alberta, 2025. https://doi.org/10.7939/81792