University of Alberta
Improving Sample Integrity in Human Fecal Metabolomics: A Comprehensive Study of Storage, Homogenization, and Stability Solutions with Applications to Crab Symbiosis
Abstract
dc:description.abstractHuman health research is advancing constantly towards the development of new diagnostic tools and improving the quality of life. Gastrointestinal (GI) disorders are among the most prevalent health challenges, and there is growing recognition of the gut's influence on overall health, including the realization that gut microbes play an important role in “training” the immune system. Indeed, the gut microbiome is at the heart of many gut diseases and may hold the key to understanding the interactions between the microbiota and host health. Despite its importance, diagnostic methods for GI conditions or assessing gut health primarily rely on invasive procedures, like endoscopies and colonoscopies. These require significant patient preparation, which can be unpleasant and time consuming. Feces have come to the forefront of metabolomics studies, offering insights into gut and gut microbiome health through non-invasive analysis. However, the transition of fecal metabolomics into clinical applications faces major barriers, particularly in the standardization of sample handling, storage, and preparation. Human feces contain undigested food, diverse microbiota, and active digestive enzymes. Such a complex matrix presents challenges for metabolomic analysis, as ongoing enzymatic and microbial activity can alter metabolite profiles after collection. Consequently, halting these activities immediately upon collection is critical, yet standardized protocols for achieving this are lacking. Ensuring minimal changes to the fecal metabolite profile post-collection currently is addressed by flash-freezing or lyophilization. However, studies have not compared these methods to freshly collected feces. Moreover, fecal heterogeneity complicates reproducibility, as inadequate homogenization can lead to inconsistent data. Bead-beating homogenization, widely used in genomics and transcriptomics, offers customizable options for achieving adequate sample homogenization while enabling intracellular metabolite extraction. However, its application in fecal metabolomics remains underexplored. Ambient temperature metabolite stabilization of fecal samples also poses a challenge. Current methods often require immediate on-site processing and storage of fecal samples, reducing patient compliance and limiting widespread adoption of fecal metabolomics studies. Although fecal stabilization kits are available, their focus on preserving microbial DNA and RNA renders them ineffective for metabolite stabilization, with some chemical preservatives being incompatible with sensitive analytical instruments. DNA Genotek’s OMNImet®•GUT device was introduced to address this limitation; however, its efficacy has not been compared thoroughly with other chemical or ambient temperature metabolite preservation methods. This thesis addresses these knowledge gaps by conducting an in-depth evaluation of fecal sample storage and preparation methods using comprehensive two-dimensional gas chromatography coupled to time-of-flight mass spectrometry (GCGC-TOFMS), which is noted for its enhanced separation power and its ability to identify metabolites (including volatile metabolites) in complex biological samples, such as feces. The work compares fresh, frozen (–80 °C), and lyophilized feces, examining their effects on volatile/semi-volatile and non-volatile polar metabolites. It also investigates bead-beating with varying bead sizes and mixtures to optimize fecal sample homogenization. Additionally, six metabolite stabilization solvents, including the OMNImet®•GUT chemistry (ME-200), were assessed for their efficacy in preserving metabolites at ambient temperature over seven days. The key findings from this work include: (1) lyophilization significantly enhanced metabolite recovery compared to fresh and frozen samples, with volatile metabolites demonstrating heightened sensitivity to storage conditions; (2) bead-beating with a combination of bead sizes and organic solvent achieved optimal homogenization, improving reproducibility and metabolite recovery without requiring lyophilization; and (3) stabilization solvents minimized metabolite profile alterations in fecal samples stored at ambient temperature, with ME-200 outperforming other chemistries for global metabolomics. However, given the varying extraction efficiencies of different solvents, a compound-class-based approach is recommended for solvent selection in targeted metabolomics studies. The findings outlined in this thesis aim to guide the development of standardized fecal handling methods, enhancing the reliability of fecal metabolomics and enabling its integration into clinical testing and general health research. Finally, these innovations in fecal sample preparation hold promise for handling and analyzing other complex biological samples. To demonstrate this, the same methods developed here were applied successfully to crab gill samples, ensuring effective homogenization and metabolite extraction. This facilitated the study of symbiotic interactions between crabs and their gill microbiota through the identification of secondary metabolites, such as terpenoids, vitamin D derivatives, cycloserine, trigonelline, and amphetamine. These results showcase the broader applicability of these techniques for other non-liquid biosamples.
Degree
thesis:*- Name thesis:degree_name
- Doctor of Philosophy
- Level thesis:degree_level
- Doctoral
- Grantor
- University of Alberta
- Year dc:date.issued
- 2025
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Tarazona Carrillo, Kieran Sky
- Advisor dc:contributor.advisor
-
- Wishart, David (Biological Sciences)
Subjects
dc:subject × 10Rights
dc:rights- Statement dc:rights
-
- This thesis is made available by the University of Alberta Library with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law.
- Language dc:language.iso
- en
Identifiers
dc:identifier.*- DOI dc:identifier.doi
- https://doi.org/10.7939/81799