Correlation of Scoliotic Parameters from Ultrasound, Surface Topography, and Radiography in Adolescent Idiopathic Scoliosis
Abstract
dc:description.abstractAdolescent idiopathic scoliosis (AIS) is a three-dimensional (3D) deformity of the spine, characterized by lateral curvature, axial vertebral rotation, and thoracic hypokyphosis. AIS patients usually have radiographs taken regularly, leading to cumulative radiation exposure and an increased risk of cancer. Ultrasound (US) and surface topography (ST) are the two main radiation-free imaging methods which have been applied for AIS applications. However, no study has investigated if combining US and ST parameters can better estimate scoliotic parameters measured on radiographs. This thesis aimed to investigate the correlation of the four main radiographic parameters, including Cobb angle (CA), axial vertebral rotation (AVR), kyphotic angle (KA), and lordotic angle (LA), with the measurements from US and ST. The specific objectives were to investigate: (1) the accuracy and reliability of US measurements obtained with a newly developed wireless handheld 3D US system, (2) the accuracy and reliability of back surface measurements obtained with a low-cost handheld 3D surface scanner, (3) the correlations between radiographic, US, and ST parameters separately for right thoracic and left lumbar curves, (4) the accuracy of stepwise linear regression equations using the combination US and ST versus using only US to estimate the four main radiographic parameters. The new 3D US system was first evaluated via a clinical study. The four main scoliotic parameters were measured on radiographs, on US images obtained with a previously validated US system, and with the new US system. When comparing the two US systems, all parameters showed good results, with intra- and inter-rater intra-class correlation coefficient (ICC[2,1]) values ≥ 0.87 and mean absolute differences (MADs) between 1.4° and 3.3°. When comparing the new 3D US system with radiography, CA, AVR, and KA also showed good results with ICC[2,1] values ≥ 0.86 and MADs between 2.3° and 5.0°. However, LA showed a large discrepancy between US images and radiographs with MAD of 14.7° and ICC[2,1] value of 0.30. The discrepancy increased when LA severity increased. To obtain ST images, a low-cost handheld 3D surface scanner was used. A phantom study was first conducted. ST scans were repeated twice, and 8 distance measurements were performed and compared with measurements using a digital caliper. The mean absolute error (MAE) was 0.33 ± 0.33 mm when comparing the two ST scans, and it ranged from 0.45 mm to 0.49 mm when comparing with caliper measurements. The MAEs were under the threshold of 2 mm which was generally considered when measuring surface images. A pilot clinical study was then conducted in AIS participants, with 10 ST parameters measured, including trunk length (TL-ST), coronal balance (CB-ST), shoulder angle difference (SAD-ST), shoulder level angle (SLA-ST), scapular angle (ScA-ST), waist level angle (WLA-ST), waist asymmetry index (WAI-ST), back surface rotation (BSR-ST), kyphotic angle (KA-ST), and lordotic angle (LA-ST). All parameters showed excellent intra-rater reliability with ICC[2,1] values ≥ 0.95. Some ST parameters demonstrated moderate to good correlations with radiographic measurements (r-values from 0.49 to 0.77), including CB-ST, ScA-ST, SAD-ST, BSRl-ST, and KA-ST. Finally, a clinical study was conducted to investigate the correlations between the 4 radiographic parameters (CA-XR, AVR-XR, KA-XR, and LA-XR) with US parameters (CA-US, AVR-US, KA-US, and LA-US) and ST parameters (CB-ST, SAD-ST, SAL-ST, ScA-ST, WLA-ST, WAI-ST, BSR-ST, KA-ST, and LA-ST). Multivariate stepwise linear regression was used separately for right thoracic and left lumbar curves. US parameters alone already showed a strong relationship with radiographic parameters, as reported in the literature. Only two ST parameters (ScA-ST and CB-ST) could complement US parameters (CA-US and AVR-US) to better estimate CA-XR and AVR-XR for right thoracic curves, improving MAD from 2.57° to 2.12° for CA-XR and from 3.20° to 1.72° for AVR-XR. ST could not complement US to estimate CA-XR and AVR-XR of left lumbar curves, KA-XR, and LA-XR. In conclusion, the newly developed wireless handheld 3D US system was able to acquire accurate and reliable images for measuring CA, AVR, and KA. The low-cost handheld 3D surface scanner was also found to be accurate and reliable when measuring different ST parameters, some of which demonstrated moderate to good correlations with radiographic measurements. Combining ST and US would improve the accuracy in estimating CA-XR and AVR-XR of right thoracic curves while providing a comprehensive understanding of both internal and external deformities.
Degree
thesis:*- Name thesis:degree_name
- Master of Science
- Level thesis:degree_level
- Master's
- Grantor
- University of Alberta
- Year dc:date.issued
- 2025
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Nguyen, Thi Nhu Nguyen
- Advisors dc:contributor.advisor
-
- Lou, Edmond (Electrical & Computer Engineering)
- Le, Lawrence (Radiology & Diagnostic Imaging)
- Emery, Derek (Radiology & Diagnostic Imaging)
Subjects
dc:subject × 5Rights
dc:rights- Statement dc:rights
-
- This thesis is made available by the University of Alberta Library with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law.
- Language dc:language.iso
- en
Identifiers
dc:identifier.*- DOI dc:identifier.doi
- https://doi.org/10.7939/81936