Back to search

University of Alberta

Modeling and Fabrication of High-Performance Single-Membrane Rectangular CMUTs with Excellent Reliability

Abstract

dc:description.abstract

Ultrasound imaging and therapy are low cost, safe, and non-invasive medical techniques. A critical component of these technologies is the ultrasound transducer, which detects and transmits ultrasound. The vast majority of ultrasound transducers are fabricated using lead-based piezoelectric materials. This approach is widespread due to its relative simplicity, excellent transmit pressures, and reliability. However, alternative technologies such as capacitive micromachined ultrasound transducers (CMUTs) have demonstrated significant promise as potential replacements. CMUTs are a MEMs based technology which transmit and detect ultrasound based on the movement of an electrostatically actuated membrane. Compared to piezoelectric technologies, CMUTs have demonstrated improved sensitivity for detecting ultrasound, wider bandwidth, and easier integration with the electronics required for imaging. Despite these advantages, adoption of CMUTs into medical ultrasound systems has primarily been limited by two main factors: poor transmit performance, and long-term reliability concerns. Reliability issues arise primarily from dielectric charging effects which occur during CMUT operation. These charging effects correspond to shifts in performance and reduce device lifespan. Another important reason is that CMUTs are highly nonlinear. This nonlinearity results in membrane collapse at high bias voltages, and hysteresis effects once the membrane is collapsed. Other groups have demonstrated CMUT designs with dielectric posts below the membrane, which considerably improved reliability. However, such designs also substantially reduced performance. CMUT transmit performance is already limited due to deleterious interactions between CMUT membranes. The current paradigm for designing CMUTs involves many small membranes per array element. Unfortunately, this approach can lead to unreliable behavior and suboptimal transmit performance if these smaller membranes oscillate out of phase, or collapse at different voltages. This thesis introduces key changes to CMUT architectures to address these limitations and develop high-reliability CMUTs with enhanced performance. In contrast to the traditional approach with multiple membranes per CMUT element, we designed CMUTs with one long rectangular membrane per array element. This approach avoids problematic multiple-membrane interactions and was thus hypothesized to enhance electromechanical efficiency and transmit performance. To improve reliability without the performance trade-offs of previous approaches, we developed an insulated “electrode-post” (EP) CMUT architecture. This EP architecture features contiguous insulation through the CMUT cavity, and protruding electrodes which enhance electrostatic attraction. We also modified a previously proposed “isolated isolation post” (IIP) CMUT architecture to be fully insulated. Both of our proposed architectures substantially improved reliability without significant reductions in performance. Although the IIP architecture slightly reduced electromechanical efficiency, the improved stability at high voltages compensated for this effect. Our EP architecture not only improved reliability, but also improved receive sensitivity by as much as 50%. All rectangular CMUT architectures exhibited very high values for electromechanical efficiency and transmit efficiency. In fact, the EP rectangular CMUTs achieved electromechanical efficiency values as high as 0.95, higher than values previously reported with either piezoelectric transducers or other CMUT designs. Moreover, the fabricated rectangular CMUT architectures demonstrated transmit efficiency 2-3 times greater than comparable CMUT or piezoelectric transducer elements in the 1.5-2.0 MHz range. To fabricate our devices, it was necessary to modify previously proposed silicon fusion-bonding processes. Our modified process enabled us to fabricate our devices with very high bonding yield, which is difficult to achieve. However, one drawback of this process was reduced control over the CMUT cavity height. This thesis presents detailed instructions, recipes, best practices, and a discussion on areas where this process could be improved. Finally, we developed an analytical model to understand and optimize and understand our proposed CMUT architectures. Our approach includes electrostatic modeling and a small-signal dynamic model. These models were validated using finite element method simulations and experiments on fabricated devices. Our model indicates that larger rectangular CMUTs could be developed and may exhibit further improved performance. The simultaneous achievement of excellent reliability, high performance, good fabrication yield, and predictive analytical models may enable our proposed devices to be used in future ultrasound systems. Such devices may enhance diagnostic imaging capabilities, improve outcomes in ultrasound therapy, or facilitate new uses of ultrasound technology.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy
Level thesis:degree_level
Doctoral
Discipline thesis:degree_discipline
Microsystems and Nanodevices
Grantor
University of Alberta
Year dc:date.issued
2025

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Dew, Eric B
Advisor dc:contributor.advisor
  • Zemp, Roger (Electrical and Computer Engineering)

Subjects

dc:subject × 9

Rights

dc:rights
Statement dc:rights
  • This thesis is made available by the University of Alberta Library with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law.
Language dc:language.iso
en

Identifiers

dc:identifier.*
DOI dc:identifier.doi
https://doi.org/10.7939/81948

Chain of custody

source
Harvested from
University of Alberta
Base URL
era.library.ualberta.ca/oai
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
citation

Dew, Eric B. Modeling and Fabrication of High-Performance Single-Membrane Rectangular CMUTs with Excellent Reliability. Doctoral thesis, University of Alberta, 2025. https://doi.org/10.7939/81948