Back to search

University of Alberta

2D and 3D Ultrafast Ultrasound Imaging With Coded Excitation and Aperiodic Apertures

Abstract

dc:description.abstract

Ultrasound imaging is a widely used medical imaging modality for studying both static structures of the human body and dynamic processes. Currently, ultrasound images can be acquired at faster real-time imaging rates with lower quality with planewave imaging, or slower rates with higher quality with scanline imaging or synthetic aperture imaging. This thesis attempts to bridge the gap between imaging quality and speed by introducing novel aperiodic temporal excitations and aperiodic apertures that can be used to image fast dynamic processes with enhanced image quality in 3D at hundreds of frames per second. While scanline imaging can be made faster by simply imaging multiple lines of sight in parallel, the interference from multiple parallel beams causes a degradation in the image quality. This thesis introduces complementary pseudo-random (CPR) codes to allow for multi-line scanline imaging with minimal interference. These codes are optimized for minimal interference with a genetic algorithm. Their image quality over other imaging methods is shown with cyst simulations and experimental images, and motion simulations are performed to show how much better the CPR imaging scheme performs in the presence of motion compared to fast planewave imaging. This thesis also introduces the development of Hadamard-Aperiodic Interval (HAPI) codes, which are a near-orthogonal set of temporal codes that can be used to image the entire set of synthetic aperture transmits in parallel with minimal interference. Using these codes, this thesis shows through ultrasound simulations of tissue-mimicking cyst phantoms how ultrafast images can be obtained at over hundreds of frames per second with respectable medical imaging quality. Moving from 2D to 3D ultrasound imaging presents some challenges because a typical 3D ultrasound probe can have thousands of elements that need to be wired and their data processed, which can slow down imaging rates significantly. Current commercial solutions involve the use of integrated microbeamformer circuits to reduce the number of output elements on X-matrix probes, however these suffer from lower resolution and quality due to using approximate delay profiles. Recently, sparse 2D arrays which only have a few elements chosen in a particular pattern to reduce artifacts have been introduced as an alternative and have been shown to produce good quality images, but it has remained difficult to manufacture them especially for larger aperture sizes. This thesis attempts to solve this by introducing a novel aperiodic sparse array based on a Costas matrix. This novel aperture only has one element in every row and column which makes it easier to manufacture, and its aperiodic structure improves imaging quality. Simulations of point and cyst phantoms are presented that compare this array to other sparse apertures in the literature, and show how it can be used for imaging of wider field of views compared to other arrays. Finally, this thesis combines this aperiodic sparse array with the aperiodic temporal HAPI codes to image 3D volumes that are focused everywhere in transmit and receive at over 500 Vols/s. The efficacy and quality of this method is shown through 3D simulations of tissue-mimicking cyst phantoms. Using these novel aperiodic codes and aperiodic apertures, this thesis hopes to allow for an improved way of studying fast dynamic processes such as bloodflow of microvasculature and cardiac dynamics with much better imaging quality.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy
Level thesis:degree_level
Doctoral
Discipline thesis:degree_discipline
Biomedical Engineering
Grantor
University of Alberta
Year dc:date.issued
2025

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Kaddoura, Tarek
Advisor dc:contributor.advisor
  • Zemp, Roger (ECE)

Subjects

dc:subject × 6

Rights

dc:rights
Statement dc:rights
  • This thesis is made available by the University of Alberta Library with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law.
Language dc:language.iso
en

Identifiers

dc:identifier.*
DOI dc:identifier.doi
https://doi.org/10.7939/81964

Chain of custody

source
Harvested from
University of Alberta
Base URL
era.library.ualberta.ca/oai
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
citation

Kaddoura, Tarek. 2D and 3D Ultrafast Ultrasound Imaging With Coded Excitation and Aperiodic Apertures. Doctoral thesis, University of Alberta, 2025. https://doi.org/10.7939/81964