A Comprehensive Framework for UVGI Air Disinfection: Novel Irradiance Correction, Multi-Lamp Characterization, Dual-Wavelength Synergy, and Sustainability Assessment
Abstract
dc:description.abstractThis thesis presents an evaluation of ultraviolet germicidal irradiation (UVGI) technologies for in-duct air disinfection, with a focus on wavelength-specific performance, irradiance characterization, and sustainability in HVAC systems. A validated experimental framework was developed to characterize ultraviolet (UV) irradiance fields using four monochromatic sources: 222 nm far UVC excimer lamp, 254 nm low-pressure mercury (LP-Hg) lamp, 265 nm UVC LEDs, and 365 nm UVA LEDs. To address directional limitations of irradiance measuring sensors, a novel correction factor was introduced to account for angular detection bias. This method reduced overestimations of up to 30%, with a maximum validation error of 18% observed at farther distances from the 254 nm lamp. The framework was further extended to scalable characterization of UV LED-based configurations using single-module measurements and geometric extrapolation. Environmental sensitivity tests showed that UV lamp performance varied significantly under different airflow and temperature conditions. The 254 nm LP-Hg lamp demonstrated marked thermal sensitivity, with irradiance output increasing by 18% between 25 °C and 35 °C, but decreasing by up to 20% with rising air velocity (0.5–2 m/s). In contrast, the 222 nm excimer lamp and both UV LEDs exhibited minimal sensitivity to environmental fluctuations, offering greater operational stability for dynamic ventilation scenarios. Irradiance measurements were coupled with computational fluid dynamics (CFD) simulations of particle trajectories to estimate spatially resolved UV fluence under practical HVAC duct conditions. Experimental UVGI inactivation tests were conducted using airborne Escherichia coli as a model organism at three airflow rates (29.05, 52.16, and 79.00 m³/h), 25 °C air temperature and 40% RH. UV rate constants (k) were derived for each monochromatic wavelength exposure, revealing the\nhighest inactivation at 265 nm (k = 1.151 m²/J), followed by 222 nm (k = 0.480 m²/J) and 254 nm (k = 0.420 m²/J). UVA at 365 nm alone did not result in measurable inactivation even at fluences up to 225 J/m², confirming its limited standalone germicidal effect in air disinfection. Disinfection efficacy was strongly influenced by bioaerosol particle size. Smaller particles (0.65–2.1 μm) showed higher log reduction values compared to larger ones (2.1–7.0 μm), primarily due to reduced internal UV shielding and more uniform energy penetration. This highlights the importance of particle size considerations in system validation and dosage modeling, particularly for airborne microbial targets with variable morphology. To investigate the potential of multi-wavelength strategies, dual-wavelength configurations combining UVA (365 nm) with each UVC source (222 nm, 265 nm and 365 nm) were tested under both simultaneous and sequential exposure modes. Simultaneous exposure and UVC followed by UVA resulted in no additional effects, suggesting no photochemical interaction beyond independent action. However, sequential UVA pre-treatment followed by UVC exposure produced significant synergistic enhancement in E. coli inactivation across all tested combinations. This synergy is perhaps attributed to UVA-induced impairment of microbial repair pathways, protein synthesis, and outer membrane damage, which sensitize cells to subsequent UVC damage. These findings provide strong evidence that wavelength sequence plays a critical role in UVGI efficacy and offer mechanistic insight for optimizing UV LED based multi-wavelength designs. Finally, a comparative operational life cycle assessment (LCA) was conducted to evaluate the sustainability of each lamp technology in achieving a 3-log microbial reduction. Metrics included energy consumption, operational & total cost, and equivalent CO₂ emissions. The 254 nm lamp emerged as the most sustainable and cost-effective for continuous-use HVAC applications, while iv the 222 nm lamp offered exposure safety. The UVC 265 nm LEDs has configurational advantages at the expense of higher power and component costs. In summary, this work provides a robust and scalable methodology for irradiance characterization, inactivation performance assessment, and environmental evaluation of UVGI systems under realistic HVAC conditions. It identifies critical engineering factors, such as lamp type, airflow, particle size, and wavelength sequencing, that influence air disinfection outcomes, and offers practical design insights for the deployment of energy-efficient, effective, and sustainable in-duct UVGI technologies.
Degree
thesis:*- Name thesis:degree_name
- Master of Science
- Level thesis:degree_level
- Master's
- Grantor
- University of Alberta
- Year dc:date.issued
- 2025
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Patel, Jay Hasmukhbhai
- Advisor dc:contributor.advisor
-
- Zhong, Lexuan (Mechanical Engineering)
Subjects
dc:subject × 5Rights
dc:rights- Statement dc:rights
-
- This thesis is made available by the University of Alberta Library with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law.
- Licence dc:rights.uri
- Language dc:language.iso
- en
Identifiers
dc:identifier.*- DOI dc:identifier.doi
- https://doi.org/10.7939/83012