Back to search

University of Alberta

Active Few Shot Learning for Histopathology

Abstract

dc:description.abstract

Active Learning (AL) and Few-Shot Learning (FSL) are widely recognized as label-efficient paradigms in machine learning, particularly valuable in domains where acquiring annotated data is resource-intensive. AL strategically selects high-impact samples for expert labelling to maximize model performance with minimal annotation costs, while FSL adapts models to new tasks using only a handful of labelled examples. Despite their successes, existing approaches in both fields often underutilize the vast reservoirs of unlabelled data typically available in real-world applications. This limitation becomes critical in scenarios where annotation budgets are severely constrained but unlabelled datasets are abundant—a common challenge in histopathology image classification. In this domain, labelling high-resolution whole-slide images (WSIs) demands specialized expertise to identify subtle cellular patterns, making the process both time-consuming and costly. Current AL and FSL methods, however, rarely integrate unlabelled data systematically, leaving untapped potential for improving model robustness and reducing reliance on labelled examples. To address this gap, we present Myriad Active Learning (MAL), a novel framework that unifies self-supervised pretraining, dynamic pseudo-label updating and active learning into an optimization loop, strategically exploiting unlabelled resources to minimize reliance on labelled samples. Specifically, MAL operates through three core components: (1) A contrastive-learning encoder pretrained on unlabelled histopathology images; (2) A dynamic pseudo-label update mechanism that mitigates error accumulation in iterative learning; and (3) A hybrid uncertainty sampling strategy combining multiple techniques to maximize sample diversity and informativeness while minimizing redundancy. Experimental results on NCT and BreaKHis benchmarks demonstrate MAL’s strong performance with limited annotations. MAL outperforms both AL baselines and few-shot learning benchmarks in accuracy and F1-score under few-shot scenarios. On the other hand, it achieves a comparable test accuracy to a fully supervised algorithm while labelling only 5% of the dataset. The framework’s accuracy and label efficiency position it as a practical solution for medical imaging tasks, such as histopathology, where annotation bottlenecks remain a major obstacle to clinical adoption. Future work will explore enhanced designs and foundation model knowledge to further boost performance.

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
Master's
Discipline thesis:degree_discipline
Signal and Image Processing
Grantor
University of Alberta
Year dc:date.issued
2025

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Wang, Jingyi
Advisors dc:contributor.advisor
  • Xingyu Li, Electrical and Computer Engineering
  • Roger Zemp, Electrical and Computer Engineering

Subjects

dc:subject × 10

Rights

dc:rights
Statement dc:rights
  • This thesis is made available by the University of Alberta Library with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law.
Language dc:language.iso
en

Identifiers

dc:identifier.*
DOI dc:identifier.doi
https://doi.org/10.7939/83071

Chain of custody

source
Harvested from
University of Alberta
Base URL
era.library.ualberta.ca/oai
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
citation

Wang, Jingyi. Active Few Shot Learning for Histopathology. Master's thesis, University of Alberta, 2025. https://doi.org/10.7939/83071