University of Alberta
Dynamic Analysis and Stabilization of VSC-Based Multi-Terminal DC Grids with Power Flow Controllers
Abstract
dc:description.abstractThe high-voltage voltage-source converter (VSC)-based multi-terminal dc (MTDC) grid is a key technology for integrating offshore wind energy and enabling bulk power transmission across nations and continents. The power flow controller (PFC) is essential for future MTDC grids to mitigate potential transmission bottlenecks and ensure economical operation. In this research, the functionality of the PFC is extended to provide active damping of MTDC grid current oscillations caused by dc-side resonance in addition to power flow management. Eigenvalue and sensitivity analyses, based on comprehensive small-signal models, are conducted to evaluate the damping capability of the proposed PFC-integrated compensators and assess their dynamic coupling with the PFC control loops. DC circuit breakers (DCCBs) are crucial for interrupting faults in MTDC grids. The current limiting inductors of DCCBs can significantly influence the dynamic performance and stability of MTDC grids. However, the existing literature does not address the assessment and mitigation of the DCCB inductance impacts on the stability of an MTDC grid equipped with a PFC. In this research, eigenvalue and frequency response analyses are employed to assess the dynamic performance and stability of the MTDC grid, considering the effects of DCCBs inductances, PFCs, and converter station control parameters. Moreover, the capability of the PFC is expanded via the development of a PFC-based stabilizer to improve the dynamic performance of the MTDC grid and enhance its damping. Back-to-back and point-to-point HVDC systems can enhance cross-regional transmission capacity and power system stability. However, their use in interconnecting two extremely weak grids can compromise system stability. This research presents a comprehensive stability analysis of back-to-back and point-to-point HVDC systems to distinguish the root causes of instability mechanisms and identify the critical short-circuit ratio of the converter stations. Eigenvalue analysis, based on detailed small-signal modeling, showed that three distinct instability mechanisms, high-, low-, and medium-frequency instabilities, can compromise the operation of VSC stations under extremely weak grid conditions. Notably, medium-frequency instability observed in the point-to-point HVDC system during inverter operation is predominantly caused by the power feedforward compensation of the dc-bus voltage controller. Active compensators are designed based on participation factor analysis to mitigate the identified instabilities. Connecting MTDC grid converter stations to very long ac transmission lines creates interfaces with weak or extremely weak ac systems. This research addresses the small-signal stability of an MTDC grid equipped with a PFC under extremely weak ac system interconnections. Using a comprehensive linearized state-space model, eigenvalue analysis uncovers that beyond the well-documented low-frequency oscillations, an MTDC grid may experience unstable medium-frequency oscillations under rectifier operation of droop voltage-controlled VSCs when interfaced with an extremely weak ac system. Moreover, it was shown that the most challenging scenario is when multiple droop voltage-controlled VSCs are interfaced to very weak ac systems, with unstable low- and medium-frequency oscillations observed at short-circuit ratios of 1.4 and 1.8, respectively. Simple yet efficient low- and medium-frequency oscillation compensators are proposed to stabilize the system, and their parameters design is detailed. Multi-terminal medium-voltage dc (MVDC) grids are emerging as a promising solution for effectively integrating renewable energy resources and supplying the growing demand for dc loads, such as EV charging stations (EVCSs). However, ensuring their stable operation under varying operating conditions remains a significant challenge. This research addresses the stability and dynamic interactions of a typical MVDC grid integrating EVCSs and PV generation via dual-active-bridge converters, an ac grid via a VSC, and a PFC. Using a comprehensive linearized state-space model, eigenvalue and frequency response analyses reveal that the MVDC system stability is jeopardized during the discharging operation of EVCSs, in the presence of the power feedforward compensation loop in the dc voltage controller of the VSC; such stability challenges become more pronounced in weak ac grid connections. A novel active damping controller integrated with the PFC control strategy is proposed to stabilize the MVDC system, extending the PFC capabilities to offer system-level damping in addition to power flow management. Extensive offline and real-time simulation studies verified the analytical results and the effectiveness of the proposed compensators in enhancing the stability of MTDC grids under a wide range of practical operating conditions.
Degree
thesis:*- Name thesis:degree_name
- Doctor of Philosophy
- Level thesis:degree_level
- Doctoral
- Discipline thesis:degree_discipline
- Energy Systems
- Grantor
- University of Alberta
- Year dc:date.issued
- 2025
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Mohamed, Hassanien RA
- Advisor dc:contributor.advisor
-
- Mohamed, Yasser (Electrical and Computer Engineering)
Subjects
dc:subject × 6Rights
dc:rights- Statement dc:rights
-
- This thesis is made available by the University of Alberta Library with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law.
- Language dc:language.iso
- en
Identifiers
dc:identifier.*- DOI dc:identifier.doi
- https://doi.org/10.7939/83080