Comparison of 4DCT and 4DCBCT in measuring motion trajectory of moving targets in phantom
Abstract
dc:description.abstractStereotactic Body Radiation Therapy (SBRT) is one of the treatment regimens for lung cancer in which a high dose of radiation is delivered to the tumor in a few fractions. The involuntary movement of lungs during breathing results in the movement of lung tumor during the treatment. Thus, SBRT necessitates the use of motion resolving imaging methods both for treatment planning and image guidance. Planning 4D Computed Tomography (4DCT) and the treatment localization 4D Cone Beam Computed Tomography (4DCBCT) can resolve tumor motion. However, due to the difference in the implementation of 4DCT on a CT scanner and 4DCBCT on radiation delivery system, it is important to ensure measured motion by two systems are in congruence. Therefore, the main purpose of this thesis is to compare the measured motion trajectory of moving target in phantom between 4DCT and 4DCBCT. We imaged the moving target, undergoing regular sinusoidal and irregular patient-like motions separately, and determined the measured motion using 4DCT and 4DCBCT. We also investigated the target enlargement due to motion in 3DCBCT which does not resolve motion. The differences between the programmed and measured target motion amplitudes were determined. The results indicate that, for regular breathing waveforms, 4DCT has the smallest median difference and inter-quartile range. 4DCBCT advanced and basic methods accurately measure motion but exhibit greater variability in measured motion differences as compared to 4DCT. Superior-inferior motion measured by basic 4DCBCT is closer to that measured by 4DCT, while advanced 4DCBCT reconstruction measures smaller motion than 4DCT by nearly 1 mm on average. The natural averaging happening in the 3DCBCT is consistent with the target motion, however, the extracted motion amplitude has larger variability compared to both 4DCT and 4DCBCT. Target volume measured in the average images of 4DCT and 4DCBCT and in 3DCBCT, are nearly equal. Similarly, the target volume measured in the maximum intensity projections of 4DCT and 4DCBCT are nearly equal. In cases of irregular patient breathing patterns, 4DCT tends to measure motion more accurately compared to the programmed waveform than 4DCBCT, although this is not consistently observed across all cases. 4DCT images faster than the 4DCBCT and does not see the entire irregularity in patient waveforms. While in some cases, 4DCBCT has poor image quality due to smaller number of projections per motion phase which affects the motion measurement accuracy. Both 4DCT and 4DCBCT are capable of accurately measuring tumor motion for regularly breathing targets, with 4DCT showing slightly higher precision. Since the projected blurring due to motion in 3DCBCT has poor confidence in motion measurement, 3DCBCT should be used carefully, especially when the motion is large and expected to vary between planning and treatment sessions. For irregular breathing, performance varies depending on waveform characteristics, though 4DCBCT’s artifacts remain a limitation. These findings support the complementary roles of both modalities in SBRT planning and delivery.
Degree
thesis:*- Name thesis:degree_name
- Master of Science
- Level thesis:degree_level
- Master's
- Discipline thesis:degree_discipline
- Medical Physics
- Grantor
- University of Alberta
- Year dc:date.issued
- 2025
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Handa, Bhumika
- Advisor dc:contributor.advisor
-
- Rathee, Satyapal (Medical Physics)
Subjects
dc:subject × 3Rights
dc:rights- Statement dc:rights
-
- This thesis is made available by the University of Alberta Library with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law.
- Language dc:language.iso
- en
Identifiers
dc:identifier.*- DOI dc:identifier.doi
- https://doi.org/10.7939/83260