University of Alberta
Minimizing Aerodynamic Disturbances and Particle Release Risk of Fibrous Filters of a Novel Air Purification System
Abstract
dc:description.abstractThis study investigates the aerodynamic performance of a novel heat-based air disinfection system equipped with pleated fibrous filters. A key feature of the system is the presence of mechanical gates located upstream and downstream of the disinfection units. These gates are essential parts of the system, as they regulate airflow and isolate the units during the disinfection process. However, their movement can generate aerodynamic disturbances, which may lead to the release of particles entrapped within the filters. Thus, numerical and experimental tests were employed to investigate how gates and their movement affect the airflow. The number of gates and the rotation period during their opening and closing substantially affect the flow pattern. Thus, configurations with 1 to 4 gates on each side of the units, along with three gate movement durations, were tested. The goal was to find the best arrangement that results in the least flow agitation. Numerical simulations were conducted to analyze the transient flow characteristics. It is known that high flow acceleration, velocity, and turbulent kinetic energy (TKE) can increase aerodynamic forces on particles within the filters and therefore release particles from them. Thus, they were monitored and minimized on the filter surface by testing the different gate configurations and rotation periods. The results demonstrate that the unit with 4-gates has the least aerodynamic disturbances, and it consistently yields considerably lower TKE, maximum velocity, and acceleration compared to the other setups. Additionally, longer gate movement periods significantly reduced flow acceleration and turbulence growth, which further reduces the particle release risk. Experimental tests also confirmed that rapid gate movement triggers particle emissions from loaded filters. A 10-time rapid gate movement led to about 5% re-entrainment of the particles within the filter, and reducing the gate movement period yielded 10 times lower particle release. Overall, the results provide practical insights for the design and operation of the disinfection system with minimal hazardous particle release risk.
Degree
thesis:*- Name thesis:degree_name
- Master of Science
- Level thesis:degree_level
- Master's
- Grantor
- University of Alberta
- Year dc:date.issued
- 2025
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Rasouli, Erfan
- Advisors dc:contributor.advisor
-
- Nouri, Alireza (Civil and Environmental Engineering)
- Shahbakhti, Mahdi (Mechanical Engineering)
Subjects
dc:subject × 3Rights
dc:rights- Statement dc:rights
-
- This thesis is made available by the University of Alberta Library with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law.
- Language dc:language.iso
- en
Identifiers
dc:identifier.*- DOI dc:identifier.doi
- https://doi.org/10.7939/83301