Back to search

University of Alberta

Application of Colloidal Substrates for Measurement of Pharmaceutical Contaminants Using In-Solution Surface-Enhanced Raman Spectroscopy (SERS)

Abstract

dc:description.abstract

The presence of pharmaceutical compounds in aquatic environments has become a significant global concern in recent decades. These contaminants have been extensively detected in water bodies, mainly because conventional wastewater treatment plants are not equipped to effectively monitor or remove them. The continuous discharge of pharmaceuticals into water bodies combined with long-term exposure poses potential chronic risks to human and animal health as well as to the overall ecosystem. As a result, the need for efficient monitoring of pharmaceuticals in wastewater has prompted extensive research focused on developing sensitive, rapid, and cost-effective analytical methods for their detection and quantification. Typically, well-established analytical tools, such as high-performance liquid chromatography–mass spectrometry (LC–MS), tandem liquid chromatography–mass spectrometry (LC–MS/MS), gas chromatography–mass spectrometry (GC–MS), and tandem gas chromatography–mass spectrometry (GC–MS/MS) have been employed for the assay of pharmaceuticals in wastewater. Although these technologies offer excellent sensitivity, they come with significant limitations. High instrumentation costs, complex operation, and the need for extensive sample preparation make them impractical for large-scale or real-time monitoring in wastewater treatment plants. Surface-enhanced Raman spectroscopy (SERS) represents a compelling solution, as a non-invasive and rapid analytical technique capable of detecting pharmaceuticals with minimal or no sample pretreatment. However, detecting pharmaceutical contaminants using SERS is challenging primarily due to their extremely low concentrations in wastewater samples. Additionally, many pharmaceutical molecules exhibit weak adsorption to SERS substrates, resulting in low signal intensity and poor sensitivity. Moreover, ensuring reproducibility and stability of SERS substrates is important to ensure consistent and reliable results across different measurements or batches. This thesis describes four different approaches to develop in-solution SERS substrates aimed at addressing these challenges. The first approach involved aggregating silver nanoparticles (AgNPs) in the presence of the analyte molecule and then halting the aggregation with polyvinylpyrrolidone (PVP). This approach promotes analyte capture and retention near the hotspots regions while avoiding over aggregation and sedimentation of the nanoparticles that would diminish the SERS signal. The developed SERS substrate was stable over a period of 98 days with a 9% relative standard deviation. The second approach involved a hybrid material that combined plasmonic AgNPs and chitosan (CS) biopolymer. The synthesized nanocomposite achieved contaminant removal through adsorption while enabling detection via SERS. Moreover, molding the CS-based nanocomposite into a three-dimensional structure allowed for recycling and separation post-wastewater treatment. The third SERS substrate, Au@Ag core–shell nanoparticles, combines the structural stability of gold with the superior plasmonic properties of silver, enabling enhanced sensitivity and tunable plasmon resonance wavelength across a broad visible to near-IR range. Colloidal solutions of Au@AgNPs were applied for the direct assessment of pharmaceuticals in secondary wastewater effluent (WWE). Further modification of core-shelled nanoparticles (Au@AgNPs) was explored as the fourth solution-phase SERS substrate. A range of thiol ligands was evaluated to optimize surface chemistry for maximal SERS enhancement. 1,4-benzene dithiol (1,4-BDT)-modified Au@AgNPs provided the highest SERS enhancement compared to their unmodified counterparts and were employed for rapid detection and quantification of Ciprofloxacin in WWE. Overall, contributions of this work pave the way for a highly sensitive, rapid, and on-site in-solution SERS-based monitoring of pharmaceutical contaminants in wastewater treatment.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy
Level thesis:degree_level
Doctoral
Grantor
University of Alberta
Year dc:date.issued
2026

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Mabrouk, Ola Moataz
Advisor dc:contributor.advisor
  • McDermott, Mark (Chemistry)

Subjects

dc:subject × 7

Rights

dc:rights
Statement dc:rights
  • This thesis is made available by the University of Alberta Library with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law.
Language dc:language.iso
en

Identifiers

dc:identifier.*
DOI dc:identifier.doi
https://doi.org/10.7939/83981

Chain of custody

source
Harvested from
University of Alberta
Base URL
era.library.ualberta.ca/oai
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
citation

Mabrouk, Ola Moataz. Application of Colloidal Substrates for Measurement of Pharmaceutical Contaminants Using In-Solution Surface-Enhanced Raman Spectroscopy (SERS). Doctoral thesis, University of Alberta, 2026. https://doi.org/10.7939/83981