Back to search

University of Alberta

Automated Home Oxygen Therapy through Closed-loop Control of Inhaled Oxygen Concentration

Abstract

dc:description.abstract

Chronic obstructive pulmonary disease (COPD) is a prevalent and progressive respiratory disorder affecting millions worldwide and represents a leading cause of morbidity and mortality. Long-Term Oxygen Therapy (LTOT) is an established treatment in COPD patients with hypoxemia. LTOT is typically administered via continuous flow oxygen delivery with fixed flow rates prescribed by physicians. However, current LTOT approaches fail to consider the dynamic nature of breathing patterns and their impact on the delivered fraction of inspired oxygen (FIO2), which can lead to suboptimal oxygenation and adverse clinical outcomes. This research addresses a critical gap by developing a closed-loop, personalized oxygen delivery system that integrates accurate FIO2 estimation through real-time respiratory monitoring. The main goal of this thesis is to optimize nasal cannula oxygen therapy in home settings, ultimately improving patient outcomes and quality of life in patients with COPD. The first step of this thesis involved experimental evaluation of oxygen delivery to develop an accurate estimation of FIO2 that accounts for patient-specific breathing parameters. In vitro experiments were performed using 3D-printed replicas of upper airways representing neonates, infants, and adults, systematically varying tidal volume, inspiratory time, and nasal cannula flow rate. These investigations revealed significant non-linear dependencies of FIO2 on these parameters and identified limitations of simple flow-weighted linear models presented in previous research studies. The resulting empirical model offered improved accuracy across different age groups and flow conditions, providing a robust foundation for dynamic oxygen delivery control. The second step of the present thesis focused on designing and simulating a closed-loop control system that dynamically adjusts nasal cannula flow based on real-time estimates of FIO2 and iii peripheral oxygen saturation (SpO2). Compartmental models of respiratory and circulatory systems were adapted to reflect COPD pathophysiology and gas exchange dynamics, enabling prediction of SpO2 responses to varying pathophysiological parameters. Using these physiological models, control algorithms incorporating both SpO2 feedback and FIO2 estimation through breathing parameters measurements were developed and computationally evaluated. Results demonstrated that integrating FIO2 estimation enhanced system performance by increasing the proportion of time spent in the target SpO2 based on clinically recommended target range (88–92% for COPD), reducing risks associated with hypoxia and hyperoxia compared to fixed-flow or SpO2-only feedback approaches. The third step assessed the feasibility of implementing the proposed control system in ambulatory settings through the use of wearable sensor technology for non-invasive respiratory monitoring. A stretchable resistive strain sensor belt was calibrated against a flow sensor to accurately measure tidal volume, inspiratory time, and respiratory rate based on chest and abdominal movements. Different sensor placements were evaluated to optimize signal fidelity and measurement accuracy. Results demonstrated that individualized calibration of the respiratory sensor enabled reliable measurement of breathing parameters essential for real-time FIO2 estimation. However, the observed requirement for sensor recalibration following each removal highlights the need for further research to improve wearable technology robustness and usability for seamless integration into home-based closed-loop oxygen delivery systems. Collectively, this research established an integrated framework combining experimental characterization, physiological modeling, control algorithm development, and wearable sensor validation to advance automated, personalized oxygen therapy. By enabling responsive adjustment of oxygen flow tailored to patient-specific respiratory mechanics and oxygenation status, the iv proposed system can result in increasing oxygenation efficacy, decreasing adverse events, and promoting greater functional independence and quality of life for COPD patients receiving LTOT outside clinical settings.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy
Level thesis:degree_level
Doctoral
Grantor
University of Alberta
Year dc:date.issued
2026

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Sabz, Mozhgan
Advisors dc:contributor.advisor
  • Martin, Andrew (Mechanical Engineering)
  • Rouhani, Hossein (Mechanical Engineering)

Subjects

dc:subject × 10

Rights

dc:rights
Statement dc:rights
  • This thesis is made available by the University of Alberta Library with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law.
Language dc:language.iso
en

Identifiers

dc:identifier.*
DOI dc:identifier.doi
https://doi.org/10.7939/84019

Chain of custody

source
Harvested from
University of Alberta
Base URL
era.library.ualberta.ca/oai
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
citation

Sabz, Mozhgan. Automated Home Oxygen Therapy through Closed-loop Control of Inhaled Oxygen Concentration. Doctoral thesis, University of Alberta, 2026. https://doi.org/10.7939/84019