University of Alberta
Tumor Autocontouring and Motion Prediction for Non-Invasive Intrafractional Tumor-Tracked Radiotherapy on a Linac-MR
Abstract
dc:description.abstractIntrafractional tumor motion presents a significant challenge to delivering conformal doses to the tumor while maximizing the sparing of the surrounding healthy tissues. The recently developed hybrid linac-MR systems are capable of intrafractional MR imaging and concurrent delivery of therapeutic beam. These features of linac-MR systems enable direct monitoring and tracking of the tumor in real time, allowing for non-invasive intrafractional tumor-tracked radiotherapy (nifteRT). To perform nifteRT, the process involving image acquisition, tumor contouring, motion-and-shape prediction, and multi-leaf collimator positioning needs to be completed within the allowed system latency of 500 ms, as recommended by the American Association of Physicists in Medicine Task Group 76 report. This thesis aims to achieve the second and third step of nifteRT, which are tumor contouring and motion-and-shape prediction. For tumor contouring, a deep learning-based autocontouring algorithm has been developed. Patient-specific hyperparameter optimization using covariance matrix adaptation evolution strategy was implemented into a U-Net-based autocontouring algorithm, and its contouring accuracy was evaluated using in-vivo MR images of liver, prostate, and lung cancer patients. The mean Dice’s coefficient (DC), centroid displacement, and Hausdorff distance of the 47 patients were 0.92 ± 0.04, 1.35 ± 1.03 mm and 3.63 ± 2.17 mm, respectively, with autocontouring time of 54.2 ± 0.3 ms per image. Compared to the two benchmarking autosegmentation methods of non-optimized U-Net and nnU-Net, the developed algorithm achieved the best overall performance in terms of contouring accuracy and speed. To evaluate the contouring performance of the developed autocontouring algorithm against experts’ manual contours, the inherent intra- and inter-observer variations in manual contours were quantified for the liver, prostate, and lung patients. Autocontours generated by the developed algorithm (patient-, expert-, and session-specifically trained) were compared against manual contours from the (a) same expert, same session; (b) same expert, different session; and (c) different experts. The evaluation metrics comparing the autocontours and manual ones for (b) surpassed the manual intra-observer variations observed between two sessions, and those for (c) exceeded the manual inter-observer variations, suggesting that the consistency between autocontours and manual ones is comparable to the intra- and inter-observer variabilities observed across the three tumor sites. For motion-and-shape prediction, a principal component (PC) analysis-based future image frame prediction method has been developed. PC analysis was applied to the window of past frames to characterize recent anatomical variations. For prediction, the temporal trajectory formed by the PC scores was extrapolated using autoregression to between 0.5 and 2.0 frames beyond the window. To verify the predictive frames, integer frames were compared against the acquired frames, while non-integer frames were compared against frames generated by an AI-based video frame interpolation method. The contour analysis yielded agreement with corresponding acquired images for 1- and 2-frame predictions, with average DC scores of 0.94 ± 0.04 and 0.90 ± 0.07 for liver, and 0.90 ± 0.07 and 0.88 ± 0.09 for lung. The developed method was also benchmarked against an autoregressive model that predicts only the future tumor centroid locations, without accounting for changes in shape, and achieved superior prediction accuracy with 1–6% higher DC’s. Average calculation time of the developed method was 49 ms per predicted frame. The developed tumor autocontouring algorithm and prediction method offer a computationally efficient and accurate means of autocontouring and predicting images in real time during nifteRT. As nifteRT enables margin reduction, it provides an opportunity to achieve higher tumor control probability via dose escalation and/or lower normal tissue complications, while broadening treatment options for patients with limited alternatives.
Degree
thesis:*- Name thesis:degree_name
- Doctor of Philosophy
- Level thesis:degree_level
- Doctoral
- Discipline thesis:degree_discipline
- Medical Physics
- Grantor
- University of Alberta
- Year dc:date.issued
- 2026
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Han, Gawon
- Advisor dc:contributor.advisor
-
- Yun, Jihyun (Oncology)
Subjects
dc:subject × 10Rights
dc:rights- Statement dc:rights
-
- This thesis is made available by the University of Alberta Library with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law.
- Language dc:language.iso
- en
Identifiers
dc:identifier.*- DOI dc:identifier.doi
- https://doi.org/10.7939/84057