University of Alberta
Development of an all-optical non-contact label-free absorption microscopy system based on quadrature interferometry
Abstract
dc:description.abstractLabel-free optical imaging of thick, unprocessed biological tissue remains challenging despite its importance in many biomedical applications. Among existing label-free modalities, photoacoustic microscopy (PAM) has gained attention because it provides optical absorption contrast specific to various endogenous biomolecules in reflection-mode from optically thick samples. This contrast is otherwise attainable only in thin specimens using a trans-illumination setup. In this microscopy method, a focused pulsed laser excites the sample, and an ultrasound transducer detects the resulting pressure waves whose amplitude is proportional to optical absorption. However, the need for physical contact or an acoustic coupling medium, such as water, complicates system design, limits imaging speed and stability, and restricts applicability in scenarios where contact is impractical or undesirable. Non-contact approaches have been developed to address this issue. Photoacoustic remote sensing (PARS), for example, replaces the transducer with a continuous-wave (CW) optical beam to interrogate the excitation spot. The reflected interrogation beam is detected, and absorption contrast is extracted from its intensity modulations following each excitation pulse. PARS microscopy, implemented at various excitation wavelengths, has been applied to microvascular imaging, cell nuclei imaging, and lipid-contrast imaging. While robust, PARS, a non-interferometric approach, misses the sensitivity gains possible with interferometric readout. Interferometric approaches, however, face their own challenges that hinder the development of robust interferometric microscopy methods. The primary challenge with interferometric sensing is signal fading, which means the system's sensitivity to the modulation of interest randomly fluctuates and can even drop to zero. This issue arises from environment-induced drift in the initial phase between the interferometer's arms. Prior photoacoustic interferometric setups that attempted to solve the signal fading issue mainly resulted in systems that were not fully non-contact and required a thin coupling medium or were limited in imaging speed. This thesis presents the development of a rapid, robust, and non-contact reflection-mode absorption microscopy technique called Absorbance Mach–Zehnder Interferometric Quadrature (AMAZE-IQ or AMAZE for simplicity) microscopy. Similar to PARS, AMAZE uses two co-focused laser beams: a pulsed laser for excitation and a continuous wave (CW) laser for interrogation. However, unlike PARS, AMAZE leverages the sensitivity benefits of interferometry with consistent performance free from signal fading. AMAZE achieves this by employing optical quadrature detection, enabling simultaneous and robust detection of amplitude and phase modulations of the interrogation beam. AMAZE requires no active stabilization or vibration isolation. Using ultraviolet excitation (UV-AMAZE), we demonstrate label-free imaging of cell nuclei in both fresh unprocessed tissue and formalin-fixed paraffin-embedded (FFPE) samples. In fresh mouse tissue, UV-AMAZE achieved up to 24 dB improvement in signal-to-noise ratio (SNR) compared to UV-PARS. Furthermore, AMAZE phase readout provides absorption contrast from thin metal films, where PARS fails. Altogether, the results establish AMAZE as a sensitive, label-free absorption microscopy method suitable for various applications, including slide-free virtual histology, endoscopic imaging, and label-free flow cytometry.
Degree
thesis:*- Name thesis:degree_name
- Master of Science
- Level thesis:degree_level
- Master's
- Discipline thesis:degree_discipline
- Biomedical Engineering
- Grantor
- University of Alberta
- Year dc:date.issued
- 2026
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Masoumi, Mohammad Hadi
- Advisor dc:contributor.advisor
-
- Zemp, Roger (Electrical and Computer Engineering)
Subjects
dc:subject × 27- optical microscopy
- photoacoustic
- microscopy
- histology
- nuclei
- Ultraviolet
- Deep ultraviolet
- interferometry
- quadrature
- optical hybrid
- 90-degree
- mach-zehnder
- all-optical
- non-contact
- absorption
- label-free
- slide-free
- reflection-mode
- phase
- amplitude
- coherent detection
- quadrature detection
- initial phase drift
- signal fading
- phase drift
- sensitivity fluctuation
- robust
Rights
dc:rights- Statement dc:rights
-
- This thesis is made available by the University of Alberta Library with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law.
- Language dc:language.iso
- en
Identifiers
dc:identifier.*- DOI dc:identifier.doi
- https://doi.org/10.7939/84075