University of Alberta
Biomechanical Gait Analysis in Transfemoral Prosthesis Users Before and After Osseointegration Surgery
Abstract
dc:description.abstractIntroduction: While socket-suspended prostheses can enhance daily function and independence in individuals with transfemoral amputation, they are often associated with complications such as pressure, pain, skin irritation, and excessive sweating, leading to reduced use of the prosthesis. Osseointegration, which involves the direct connection between the bone and a titanium implant, is an emerging technique designed to overcome these socket-related challenges by enabling the direct attachment of bone-anchored prostheses (BAP). BAP have been shown to improve mobility and quality of life; however, longitudinal data on the biomechanical gait changes following osseointegration remain limited. Instrumented gait analysis is an objective way to identify deviations from normal walking by quantifying temporal-spatial, kinematic, kinetic, and electromyography data. However, the accuracy of biomechanical data can be significantly compromised by soft tissue artifacts (STA), particularly in individuals with amputation, where residual limb soft tissues can move independently relative to the femur. Objectives: The overall goal of this work is to provide evidence on the effect of using BAP on the gait of individuals with transfemoral amputation, assessing whether temporal-spatial and kinematic parameters change over time after osseointegration surgery compared to baseline with a socket prosthesis and whether they become closer to unimpaired gait patterns. The specific objectives are to: 1) identify an optimal methodological approach to reduce STA, by examining the differences in the angular kinematics when using the standard thigh marker versus a new “implant marker” which represents the exact movement of the femur; 2) evaluate temporal-spatial changes (e.g., velocity, cadence, step width, and etc.) at 6 and 12 months post-OI surgery compared to baseline with a socket prosthesis; 3) examine kinematic changes (e.g., trunk, pelvis, and hip range of motion) at 6 and 12 months post-OI surgery compared to baseline with a socket prosthesis. Methods: Six adult participants with unilateral transfemoral amputation and one participant with left transfemoral and right transtibial amputations participated in this study. All participants received a transfemoral BAP with an osseointegrated prosthetic limb (OPL) implant. Kinematic and temporal-spatial data were collected at baseline while using a socket prosthesis, and 6 and 12 months after osseointegration surgery using a transfemoral BAP. The prosthetic components were consistent for each participant across all time points. Data were obtained using an 8-camera optoelectronic motion capture system. Passive markers were placed on the trunk and lower extremities of the participant and tracked at 120 Hz during several walking trials at a comfortable walking speed. Equivalent marker locations were identified on the prosthesis, with an additional marker placed on the implant stem above the knee joint connector for more accurate tracking of the femur. Comparisons were performed across the three time points to evaluate changes in gait kinematics and temporal-spatial parameters following the transition from a socket-suspended prosthesis to BAP. Results: In individuals using BAP, incorporating an implant marker provided a more accurate tracking of femoral and knee joint motion compared to a traditional thigh marker on the skin of the residual limb. This marker selection helps reduce STA errors in measuring angular kinematic in transfemoral osseointegrated gait. Building on this methodological advantage, we examined longitudinal gait data over time following osseointegration surgery. For the participant with bilateral amputations (transfemoral and transtibial), gait data collected over a two-year period post-osseointegration of the femur showed notable improvements in cadence, walking velocity, pelvic rotation, and hip kinematics. The most notable findings in participants with unilateral amputation following osseointegration included an increased step width at 12 compared to 6 months, increased step length on the amputated side accompanied by a decrease on the intact side, improved trunk and pelvic rotation, and reduced hip rotation on the amputated side at 12 months compared to baseline. However, individual variation was high as not all participants followed the averaged group trends. Conclusions: This study contributes to the understanding of how gait changes over time following osseointegration surgery in individuals with transfemoral amputation, emphasizing the value of accurate motion tracking using implant markers. To advance this work, future research should include larger, more consistent participant groups and combine biomechanical data with kinetic, muscle activity, and clinical outcome measures. Considering individual factors affecting participant gait is also important when determining relevant gait changes. This integrated approach will offer a better understanding of gait changes after osseointegration.
Degree
thesis:*- Name thesis:degree_name
- Doctor of Philosophy
- Level thesis:degree_level
- Doctoral
- Discipline thesis:degree_discipline
- Rehabilitation Science
- Grantor
- University of Alberta
- Year dc:date.issued
- 2026
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Ravari, Reihaneh
- Advisor dc:contributor.advisor
-
- Hebert, Jacqueline (Medicine)
Subjects
dc:subject × 5Rights
dc:rights- Statement dc:rights
-
- This thesis is made available by the University of Alberta Library with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law.
- Licence dc:rights.uri
- Language dc:language.iso
- en
Identifiers
dc:identifier.*- DOI dc:identifier.doi
- https://doi.org/10.7939/84403