Back to search

University of Alberta

Preclinical Development of Intraspinal Microstimulation: Neural Mapping, Feasibility, and Implant Technology

Abstract

dc:description.abstract

The overall goal of the work described in this thesis is to develop an intervention for restoration of standing and walking after complete spinal cord injury (SCI) in humans. The focus of this work is on preclinical testing of intraspinal microstimulation (ISMS) and advancing it towards first in-human use. ISMS is a novel technique for restoration of lost motor function after SCI. It involves implantation of penetrating microelectrodes inside the spinal cord. By delivery of focal spatiotemporal electrical pulses through microelectrodes implanted in the lumbar enlargement, ISMS activates the preserved motor networks below the level of injury. Preclinical research has demonstrated that ISMS can recruit coordinated muscle groups spanning one or more joints, effectively engaging functional motor synergies even in the presence of complete spinal cord transection. When combined with physiologically inspired control strategies, ISMS has been shown to support stable, weight-bearing standing and overground walking. Notably, these movements exhibit significantly greater fatigue resistance compared to those elicited by intramuscular stimulation. These findings highlight ISMS as a promising approach for restoring leg function after completing spinal cord injury in humans. This thesis focuses on the development of ISMS implants suitable for human use and evaluates their feasibility, safety, and functional performance through implantation in large animal models (pigs) that closely resemble human spinal cord anatomy. The central question addressed in this thesis is whether an ISMS implant can remain stable in the spinal cord of a pig undergoing a wide range of motion comparable to that of humans. To investigate this, three key objectives were defined: 1) Define implant targeting requirements: Determine the anatomical and functional criteria necessary for stimulating the appropriate spinal networks involved in generating diverse leg movements required for overground walking. 2) Assess surgical feasibility and safety: Evaluate whether it is safe and practical to perform electrode implantation and motor mapping procedures in the human spinal cord, which are essential prerequisites for translation of ISMS to humans. 3) Develop suitable implant technology: Design and fabricate implants that fulfill the material, electrochemical, and mechanical requirements necessary for safe neural stimulation and long-term stability. To address the first objective, we conducted detailed spinal cord mapping in domestic pigs to define the requirements for targeting all key motor outputs necessary for overground walking. This study provided the first functional map of the lumbosacral enlargement in pigs. Our findings demonstrated that ISMS can reliably evoke a range of functional leg movements in pigs, similar to those observed in non-human primates and rodents. Moreover, the organization of motoneuronal pools in pigs showed strong similarities to the established maps in monkeys, cats, and rats, particularly in the rostrocaudal, mediolateral, and dorsoventral dimensions. The results of the first study establish the anatomical and functional parameters needed for successful implant targeting. Importantly, they confirm that functional motor maps are preserved across species, supporting the use of pig, monkey, and cat data to guide the initial clinical translation of ISMS in humans. To address the second goal and assess the safety and functional impact of intraoperative spinal cord mapping, we conducted two complementary studies in Yucatan minipigs (YMPs). First, we established baseline kinematic and EMG profiles of overground walking in neurologically intact animals across a range of speeds (Appendix). Then, we performed spinal mapping using penetrating microelectrodes and showed that this procedure did not produce lasting motor deficits or significant tissue damage. Postoperative gait kinematics and EMG activity recovered to baseline levels, supporting the clinical feasibility of such mapping procedures for guiding ISMS implantation in humans. To address the third goal of the thesis, developing proper implants for safe stimulation and long- term spinal implantation, we iteratively designed and validated two generations of ISMS systems in domestic pigs. We began by designing a fully implantable ISMS system with 16 microwire- based electrodes integrated with a strain-relief mechanism. This design was informed by prior anatomical studies in domestic pigs, which characterized thoracolumbar spinal motion and quantified the low dislodgment forces required to extract electrodes from pig spinal cord tissue. The strain-relief structure was intended to accommodate spinal movement and reduce chronic micromotion forces that contribute to foreign body response (FBR). Long-term testing in pigs (up to four weeks) confirmed the surgical feasibility, functional efficacy, and positional stability of the microwire-based implants. Despite the improved compliance, the inherent mechanical mismatch between rigid microwires and soft neural tissue remained a concern for chronic implantation. To further mitigate FBR and improve chronic stability, we developed FLEX-ISMS, a flexible thin-film electrode array featuring 14 polyimide arms with integrated serpentine strain-relief elements and 42 microelectrode sites. Flexible arms were implanted using precision laser-fabricated insertion aids, which enabled targeted delivery of the flexible shanks deep into the spinal cord with minimal acute damage. Functional testing demonstrated selective, graded activation of joint movements across the hindlimb, while histology confirmed that acute tissue disruption from FLEX-ISMS was comparable to that of traditional microwires. These results validate FLEX-ISMS as a promising next-generation ISMS platform, combining mechanical compliance, functional selectivity, and minimal tissue response laying the foundation for chronic implantation in spinal cord injury models. Collectively, this thesis established the anatomical, surgical, and engineering foundations necessary for chronic ISMS in large animal models and defined key design and safety requirements to guide future clinical translation of ISMS in humans.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy
Level thesis:degree_level
Doctoral
Grantor
University of Alberta
Year dc:date.issued
2025

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Mirkiani, Soroush
Advisor dc:contributor.advisor
  • Vivian Mushahwar (Medicine & Dentistry)

Subjects

dc:subject × 6

Rights

dc:rights
Statement dc:rights
  • This thesis is made available by the University of Alberta Library with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law.
Language dc:language.iso
en

Identifiers

dc:identifier.*
DOI dc:identifier.doi
https://doi.org/10.7939/85637

Chain of custody

source
Harvested from
University of Alberta
Base URL
era.library.ualberta.ca/oai
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
citation

Mirkiani, Soroush. Preclinical Development of Intraspinal Microstimulation: Neural Mapping, Feasibility, and Implant Technology. Doctoral thesis, University of Alberta, 2025. https://doi.org/10.7939/85637