University of Alberta
Force Sensor-Assisted Ultrasound System and Automated Muscle Parameter Analysis
Abstract
dc:description.abstractWith the increasing focus on preventive medicine, muscle assessment has gained significant clinical importance, particularly in the context of conditions such as sarcopenia, which is associated with poor muscle quantity and quality. While many imaging modalities can be used for muscle evaluation, ultrasound (US) offers a more accessible, cost-effective, and real-time alternative. However, ultrasound remains highly operator-dependent, introducing variability due to factors such as probe orientation, position, and the amount of applied force. In particular, the lack of standardized probe force can lead to inconsistent quantitative measurements, such as muscle thickness. Additionally, ultrasound image analysis is often time-consuming and subjective, varying with acquisition protocols and rater expertise. This thesis aimed to address these challenges through the following three main objectives: (1) to develop a compact, wireless force sensor system that can be integrated with a portable ultrasound scanner to investigate the relationship between applied probe force and muscle thickness; (2) to validate the reliability of both the force sensor system and image-based thickness measurements across different raters and acquisition sessions; and (3) to implement and evaluate an automated image analysis pipeline that enables consistent, efficient extraction of muscle parameters, reducing the need for manual measurements. The force sensor system was first developed and evaluated through laboratory experiments. Three custom-designed 3D-printed housings were tested to assess their effects on sensor sensitivity and protection against ultrasound gel. The final configuration, using a padding-nub housing, achieved an accuracy of 0.022 N, sensitivity of 364 mV/N, repeatability of 0.383%, and reproducibility of 0.436%, confirming the system’s capability for precise force measurement. To validate clinical utility, two reliability studies were conducted. The first study evaluated muscle thickness measurements on standardized images and demonstrated strong agreement across raters, with an intra-rater ICC[2,1] of 1.0 and an inter-rater ICC[2,1] of ≥ 0.99 for inter-rater, confirming the consistency of image-based analysis. The second study investigated force-thickness compression reproducibility using the developed force-sensing ultrasound system. Quadratic regression models were fitted to compare muscle deformation under applied force across raters and time points. ICC[2,1] values for both rectus femoris and vastus intermedius muscles exceeded 0.99, with coefficient of variation (CV) ≤ 3.28% and standard error of measurement (SEM) ≤ 0.004 for intra-rater, and ICC[2,1] = 0.998, CV ≤ 3.32%, and SEM ≤ 0.002 for inter-rater, supporting the system’s ability to capture reproducible muscle responses under applied force. Finally, an automated analysis pipeline was developed to extract muscle parameters (e.g echogenicity and thickness) from static ultrasound images. The pipeline, which incorporated a deep learning-based segmentation model (nnUNet), was integrated into a user-friendly interface. When compared with manual measurements, the automated method demonstrated near-identical results, with a mean difference of 0.12 (p = 0.085) for average pixel intensity and ICC values ≥ 0.999 for thickness, significantly reducing analysis time and rater variability. In conclusion, this thesis presents a reliable force sensor-integrated system capable of accurately measuring probe pressure during ultrasound scanning and a robust automated pipeline for consistent muscle analysis. Together, these tools have the potential to enhance the reproducibility and efficiency of ultrasound-based muscle assessment, supporting their application in both research and clinical practice.
Degree
thesis:*- Name thesis:degree_name
- Master of Science
- Level thesis:degree_level
- Master's
- Grantor
- University of Alberta
- Year dc:date.issued
- 2025
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Dinh, Hoang Bao Vy
- Advisors dc:contributor.advisor
-
- Le, Lawrence (Radiology and Diagnostic Imaging)
- Lou, Edmond (Electrical and Computer Engineering)
Subjects
dc:subject × 5Rights
dc:rights- Statement dc:rights
-
- This thesis is made available by the University of Alberta Library with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law.
- Language dc:language.iso
- en
Identifiers
dc:identifier.*- DOI dc:identifier.doi
- https://doi.org/10.7939/85650